1-38
Sun Fire V1280/Netra 1280 Systems Installation Guide • May 2006
1. Connect the 10/100 LOM Ethernet port to the chosen administrative console (local
hub, router, or switch).
For 10/100 LOM Ethernet
port connector information
, see “10/100 LOM Ethernet
Port” on page A-9.
2. Set up the chosen administrative console.
Refer to the
Sun Fire V1280/Netra 1280 System Administration Guide.
1.8
Connecting the I/O Assemblies
The I/O assemblies provide network interface and peripheral access to the system
domains.
1. Connect one end of the I/O Ethernet cable to the Net0/Net1 Ethernet port
(
.
2. Connect the other end of the I/O Ethernet cable to the hub, workstation, or
peripheral.
1.9
Powering On the System
1. Turn the power switch to the On positio
n
.
2. Power on the system.
Refer to the
Sun Fire V1280/Netra 1280 System Administration Guide
.
1.10
Powering Off the System
1. Notify users that the system is going down.
2. Back up the system files and data to tape, if necessary.
3. Halt the Solaris operating system.
Refer to the
Sun Fire V1280/Netra 1280 System Administration Guide
.
4. Wait for the system-halted message and the boot monitor prompt.