background image

Please

Recycle

Copyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.

Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without

limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or

more additional patents or pending patent applications in the U.S. and in other countries.

This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and

decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of

Sun and its licensors, if any.

Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.

Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in

the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.

Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Sun Fire, Netra, OpenBoot, and Solaris are trademarks or registered

trademarks of Sun Microsystems, Inc. in the U.S. and in other countries.

All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other

countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc.

The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges

the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun

holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN

LOOK GUIs and otherwise comply with Sun’s written license agreements.

U.S. Government Rights—Commercial use. Government users are subject to the Sun Microsystems, Inc. standard license agreement and

applicable provisions of the FAR and its supplements.

DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright 2006 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés.

Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la

limitation, ces droits de propriété intellectuels peuvent inclure un ou plus des brevets américains énumérés à http://www.sun.com/patents et

un ou les brevets plus supplémentaires ou les applications de brevet en attente dans les Etats-Unis et dans les autres pays.

Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la

décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans

l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y ena.

Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des

fournisseurs de Sun.

Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque

déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.

Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, Sun Fire, Netra, OpenBoot, et Solaris sont des marques de fabrique ou des

marques déposées de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays.

Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc.

aux Etats-Unis et dans d’autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun

Microsystems, Inc.

L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun

reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique

pour l’industrie de l’informatique. Sun détient une license non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence

couvrant également les licenciées de Sun qui mettent en place l’interface d ’utilisation graphique OPEN LOOK et qui en outre se conforment

aux licences écrites de Sun.

LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFAÇON.

Содержание Sun Fire V1280

Страница 1: ...Sun Microsystems Inc www sun com Submit comments about this document at http www sun com hwdocs feedback Sun Fire V1280 Netra 1280 Systems Installation Guide Part No 817 3334 12 May 2006 Revision A...

Страница 2: ...NVALID Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propri t intellectuels relatants la tec...

Страница 3: ...Position 1 7 1 1 4 2 Installing the Rail Assemblies in the Top Position 1 8 1 1 5 Installing the Rail Assemblies in a Sun Rack 900 Cabinet 1 9 1 1 5 1 Installing the Rail Assemblies in the Bottom Posi...

Страница 4: ...ication 1 34 1 7 Connecting Consoles to the System Controller 1 35 1 7 1 Connecting the Initial Administrative Console 1 36 1 7 2 Connecting the Administrative Console 1 37 1 8 Connecting the I O Asse...

Страница 5: ...tents v A 3 2 1 Connecting to a Male 9 Pin D Type Serial Port A 8 A 4 10 100 LOM Ethernet Port A 9 A 4 1 Twisted Pair Ethernet Cable Type Connectivity A 9 A 5 Net0 Net1 Ethernet Ports A 10 Index Index...

Страница 6: ...vi Sun Fire V1280 Netra 1280 Systems Installation Guide May 2006...

Страница 7: ...radle 1 15 FIGURE 1 9 Aligning the Slides 1 16 FIGURE 1 10 Removing the Shipping Cradle 1 17 FIGURE 1 11 Pushing the System into the System Cabinet 1 18 FIGURE 1 12 Tightening the Securing Screws 1 18...

Страница 8: ...ce B Plastic Cover Removed and Connectors Exposed 1 33 FIGURE 1 25 Netra 1280 Power Feed Connectors 1 34 FIGURE 1 26 System Controller and I O Assembly Locations 1 37 FIGURE A 1 External I O Connectio...

Страница 9: ...6 TABLE A 4 Default Settings for Connecting to Serial A A 7 TABLE A 5 Pin Interconnections Performed by the Sun DB 25 Adapter A 7 TABLE A 6 Pin Interconnections Performed by a DB 9 9 pin Adapter A 8...

Страница 10: ...x Sun Fire V1280 Netra 1280 Systems Installation Guide May 2006...

Страница 11: ...broad selection of Sun documentation including localized versions at http www sun com documentation Application Title Safety Sun Fire V1280 Netra 1280 Systems Compliance and Safety Manual Use Sun Fir...

Страница 12: ...com hwdocs feedback Please include the title and part number of your document with your feedback Sun Fire V1280 Netra 1280 Systems Installation Guide part number 817 3334 12 Tools Required For the pr...

Страница 13: ...1 Installing Slides and Rails on page 1 2 Section 1 2 Installing the System in a Cabinet on page 1 12 Section 1 3 Installing Slide Rail Locking Nuts on page 1 19 Section 1 4 Installing the Cable Manag...

Страница 14: ...kit This kit includes the following Two slide lock spacers Two slide lock nuts Four rails two inner and two outer 8 mm wrench Note If you received your system pre einstalled in a cabinet you may proce...

Страница 15: ...outer slides Front bracket FIGURE 1 1 Rail Assembly Standard Configuration Adjust the position of the rear bracket or the adjustable bracket to modify the length of the assembly The slide assembly an...

Страница 16: ...ide rail assembly 2 Push up on the inner slide so that the locating tab on the side of the system clips over the cutouts in the slide FIGURE 1 2 The spring tab should engage Note The spring clips must...

Страница 17: ...Chapter 1 Physical Installation 1 5 FIGURE 1 2 Spring Clips and Cutouts...

Страница 18: ...emove the four nuts securing the front bracket 3 Rotate the front bracket 180 degrees and resecure it facing inward FIGURE 1 3 4 Remove the four nuts that secure the rear bracket 5 Rotate the rear bra...

Страница 19: ...the rear bracket and resecure the adjustable bracket 2 Adjust the length of each rail assembly a Loosen the four nuts that secure the rear bracket b Reposition the rear bracket to the location marked...

Страница 20: ...he bracket in place until it is secured 2 Secure the adjustable bracket into cabinet holes 60 and 67 with two no 10 32 UNF screws 3 Secure the front bracket into cabinet holes 60 and 67 with two no 10...

Страница 21: ...1 Installing the Rail Assemblies in the Bottom Position 1 Insert the pins in the front bracket into cabinet holes 22 and 33 FIGURE 1 5 The pins will hold the bracket in place until the bracket is sec...

Страница 22: ...etra 1280 Systems Installation Guide May 2006 FIGURE 1 5 Installing the Rails in a Sun Rack 900 Cabinet or 19 Inch Four Post Cabinet Rear bracket secured to outer cabinet holes Front bracket secured t...

Страница 23: ...bly a Loosen the four nuts that secure the rear bracket b Reposition the rear bracket to the appropriate markings shown on the slide assembly and resecure the rear bracket 3 Secure the rear bracket wi...

Страница 24: ...rt the rackmount securing screws no lower than 18 5 inches and 22 5 inches 47 0 cm and 57 2 cm respectively Refer to the Sun Fire V1280 Netra 1280 Slide Rail Installation Instructions and Mounting Tem...

Страница 25: ...Chapter 1 Physical Installation 1 13 c Repeat Step a and Step b for the second front bezel door FIGURE 1 6 Releasing the Door Hinge Mechanism...

Страница 26: ...Netra 1280 Systems Installation Guide May 2006 2 Remove the shipping cradle bolts FIGURE 1 7 The bolts secure the orange metal shipping cradle to the wooden pallet FIGURE 1 7 Removing the Shipping Cra...

Страница 27: ...ve the system safely into the cabinet using a computer equipment lift 1 Extend the cabinet stabilizer and lock it in position as applicable Caution The shipping cradle must be attached when the system...

Страница 28: ...abinet and latch them in the extended position 5 Lift the system until it is level with the outer slides on the cabinet 6 Carefully move the lifting device forward until the slides on the system are f...

Страница 29: ...device still supporting the system loosen the four captive screws attaching the handles of the shipping cradle to the system 8 Pull both shipping cradle handles away from the system This disconnects t...

Страница 30: ...URE 1 11 FIGURE 1 11 Pushing the System into the System Cabinet 11 Tighten the two securing screws on the front of the system to secure the system in the cabinet FIGURE 1 12 12 Retract the cabinet sta...

Страница 31: ...each system prior to moving a cabinet with one or more systems The following procedure is used to secure systems in cabinets when a freestanding system is ordered along with a slide rail kit for moun...

Страница 32: ...nd Tightening the Slide Rail Spacers 4 Slide the system into the system cabinet 5 From the rear of the system insert and tighten the locking nut FIGURE 1 14 FIGURE 1 14 Inserting and Tightening the Sl...

Страница 33: ...nd CMA 800 The optimum choice of CMA is dependant upon the available depth in the cabinet and the quantity or type of cable to be supported Use the CMA Lite if the larger CMA 800 management arm does n...

Страница 34: ...using the two captive screws FIGURE 1 16 2 Secure the center pivot point of the CMA to the inside rear of the left hand rail assembly using the two captive screws 3 Secure the pivot at the end of the...

Страница 35: ...17 throughout the following procedure for identification and orientation of CMA parts FIGURE 1 17 Upper Lower CMA Arms and Left Hand Right Hand T Brackets Upper pivot bracket Hinge pin Hinge pin Upper...

Страница 36: ...pin securing the pivot bracket to the upper CMA arm which will facilitate attaching the bracket to the system chassis 3 Secure the pivot bracket to the upper left hand side of the system chassis usin...

Страница 37: ...5 After attaching the pivot bracket to the chassis use the hinge pin removed previously to secure it to the upper CMA arm FIGURE 1 19 FIGURE 1 19 Attachment of Upper CMA Arm and Pivot Bracket Upper pi...

Страница 38: ...et to the system chassis 5 Secure the pivot bracket to the lower left hand of the system chassis using the two captive screws see FIGURE 1 18 6 After attaching the bracket to the chassis secure the lo...

Страница 39: ...ter 1 Physical Installation 1 27 7 Secure the left hand T bracket to the left hand slide rail using two captive screws FIGURE 1 21 FIGURE 1 21 Attaching Left Hand T Bracket Slide rail Left hand T brac...

Страница 40: ...ra 1280 Systems Installation Guide May 2006 8 Secure the right hand T bracket to the right hand slide rail using two captive screws FIGURE 1 22 FIGURE 1 22 Attachment of Right Hand T Bracket Slide rai...

Страница 41: ...T Bracket 10 Secure the lower CMA arm to the left hand T bracket using a single hinge pin FIGURE 1 23 11 Route the cabling through the cable channels as desired and then secure both the upper and lowe...

Страница 42: ...system power switch to the Standby position Caution The On Standby power switch does not isolate the equipment The AC power cords are the primary means of disconnection for this product 2 Turn the cab...

Страница 43: ...tomer supplied power source A circuit breakers and Source B on the cabinet to the customer supplied power source B circuit breakers Refer to the installation guide that came with the cabinet for instr...

Страница 44: ...alified electrician 1 Turn the power switch to the Standby position Caution The On Standby power switch does not isolate the equipment The circuit breakers are the primary means of disconnection for t...

Страница 45: ...tem e Ensure that an earth strap for each feed pair is connected to the electrical earth studs FIGURE 1 24 5 Secure the plastic covers with the Phillips no 2 screws FIGURE 1 24 DC Inlet Box With Sourc...

Страница 46: ...the Power Input Connections Prior to the Initial Power Application Note The following procedure is intended as a guide only and should only be performed by a qualified electrician Caution Ensure the...

Страница 47: ...rms The LOM command line interface and the Solaris OpenBoot PROM console are accessed by connecting an administrative console to either serial port A or the 10 100 LOM Ethernet port The administrative...

Страница 48: ...the Serial A port 1 Connect the administrative console to the Serial A port The Serial A port is a DTE data terminal equipment port An adapter cross over or null modem cable is required to connect th...

Страница 49: ...t Note Communication on the Serial A port is possible but is subject to interruption by the LOM device Refer to the Sun Fire V1280 Netra 1280 System Administration Guide AC 3 AC 2 AC 1 AC 0 SOURCE A S...

Страница 50: ...al access to the system domains 1 Connect one end of the I O Ethernet cable to the Net0 Net1 Ethernet port FIGURE 1 26 2 Connect the other end of the I O Ethernet cable to the hub workstation or perip...

Страница 51: ...boards refer to the Sun Fire V1280 Netra 1280 Systems Service Manual for instructions Caution During initial installation turn off the power at the circuit breakers before removing or replacing syste...

Страница 52: ...com for the mounting hole numbers of the mounting screws for Sun Microsystems disk arrays other storage trays and devices Unless otherwise specified in the Rackmount Placement Matrix mount the heavies...

Страница 53: ...al system controller ports one reserved 10 100 LOM Ethernet port system controller Ethernet port Net0 Net1 Ethernet port Two gigabit Ethernet RJ 45 ports FIGURE A 1 External I O Connections Sun Fire V...

Страница 54: ...and 1 2 and 3 and 4 and 5 A 1 1 PCI IB_SSC Assemblies PCI IB_SSC assemblies provide six I O slots labeled 0 through 5 When viewing the rear of the system slot 0 is on the left and slot 5 is on the ri...

Страница 55: ...ound GND 5 DB P1 I O 28 C D I O 51 Termpwr POWER 6 DB 0 I O 29 REQ I O 52 Termpwr POWER 7 DB 1 I O 30 I O I O 53 Reserved NA 8 DB 2 I O 31 DB 8 I O 54 Ground GND 9 DB 3 I O 32 DB 9 I O 55 ATN I O 10 D...

Страница 56: ...s 82 ft 25 meter for low voltage differential point to point interconnect For PCI PCI X compatible IB_SSC assemblies the embedded SCSI subsystem is SCSI Ultra 320 UltraSCSI low voltage differential pa...

Страница 57: ...nal Name Description State 1 Not connected 2 Not connected 3 Not connected 4 Not connected 5 SYSTEM_NO UNIX Running Normally open 6 SYSTEM_NC UNIX Running Normally closed 7 SYSTEM_COM UNIX Running Com...

Страница 58: ...ors FIGURE A 4 These ports are also known as the system controller serial ports TABLE A 3 lists the pinout information FIGURE A 4 RJ 45 Serial Connectors Note Serial port B is reserved TABLE A 3 RJ 45...

Страница 59: ...er supplied with your system part number 530 2889 or an alternative adapter that performs the same pin interconnections The Sun supplied DB 25 adapter enables you to connect to any Sun system TABLE A...

Страница 60: ...25 adapter to an adapter that has one 25 way female connector and one 9 way D type female connector Sun does not supply a 25x9 way D type female to female adapter 3 Connect the male end of a 9 pin se...

Страница 61: ...twisted pair STP cable Category 3 STP 3 voice grade Category 4 STP 4 Category 5 STP 5 data grade For 100BASE T applications shielded twisted pair category 5 STP 5 data grade cable TABLE A 7 Twisted p...

Страница 62: ...rs FIGURE A 6 The Net0 Net1 Ethernet ports are also known as the gigabit Ethernet RJ 45 ports TABLE A 9 lists the pinout information FIGURE A 6 RJ 45 Gigabit Ethernet Connectors TABLE A 9 RJ 45 Gigabi...

Страница 63: ...Index 1 Index C cable lengths STP 5 A 9 connectivity TPE A 9 E Ethernet TPE connectivity A 9 external cables lengths A 9 R retention nut installing 1 19 retention washer installing 1 19...

Страница 64: ...Index 2 Sun Fire V1280 Netra 1280 Systems Installation Guide May 2006...

Отзывы: