1-28
Sun Netra T5220 Server Service Manual • January 2012
service
Runs POST with preset values for
diag_level
and
diag_verbosity
.
diag_level
max
If
diag_mode
=
normal
, runs all the minimum
tests plus extensive CPU and memory tests.
min
If
diag_mode
=
normal
, runs minimum set of
tests.
diag_trigger
none
Does not run POST on reset.
user_reset
Runs POST upon user-initiated resets.
power_on_reset
Only runs POST for the first power on. This
option is the default.
error_reset
Runs POST if fatal errors are detected.
all_resets
Runs POST after any reset.
diag_verbosity
none
No POST output is displayed.
min
POST output displays functional tests with a
banner and pinwheel.
normal
POST output displays all test and informational
messages.
max
POST displays all test, informational, and some
debugging messages.
TABLE 1-7
ALOM CMT CLI Parameters Used for POST Configuration
(Continued)
Parameter
Values
Description