Sun Netra T5220 Server Service Manual • January 2012
FIGURE 5-7
Lifting the System Fan Assembly From the Chassis
5. Set the fan assembly aside on an antistatic mat.
6. Consider your next step:
■
If you removed the fan assembly as part of another procedure, return to that
procedure.
■
Otherwise, continue to
Section 5.3.2, “Installing the System Fan Assembly” on
page 5-8
.
5.3.2
Installing the System Fan Assembly
1. Remove the replacement fan assembly from its packaging and place it on an
antistatic mat.
2. Insert your forefinger and thumb into the holes at the top of the fan assembly,
squeeze them together, and lower the fan assembly into the chassis (
FIGURE 5-8
).
3. Reconnect the fan assembly cable to the power board (
FIGURE 5-8
).