Chapter 4
Replacing Motherboard Assembly Components
4-23
Note –
FB-DIMM names in ILOM messages are displayed with the full FRU name,
such as
/SYS/MB/CMP0/BR0/CH0/D0
.
4.6
Replacing FB-DIMMs
This section describes how to diagnose and replace faulty FB-DIMMs. For FB-DIMM
configuration guidelines, see
Section 4.5, “FB-DIMM Layout” on page 4-19
.
Caution –
Ensure that all power is removed from the server before removing or
installing FB-DIMMs. You must disconnect the power cables before performing this
procedure.
Branch 1
Channel 0
/SYS/MB/CMP0/BR1/CH0/D0
J1401
1
C
/SYS/MB/CMP0/BR1/CH0/D1
J1501
3
D
Channel 1
/SYS/MB/CMP0/BR1/CH1/D0
J1601
2
C
/SYS/MB/CMP0/BR1/CH1/D1
J1701
3
D
Branch 2
Channel 0
/SYS/MB/CMP0/BR2/CH0/D0
J2001
1
E
/SYS/MB/CMP0/BR2/CH0/D1
J2101
3
F
Channel 1
/SYS/MB/CMP0/BR2/CH1/D0
J2201
2
E
/SYS/MB/CMP0/BR2/CH1/D1
J2301
3
F
Branch 3
Channel 0
/SYS/MB/CMP0/BR3/CH0/D0
J2401
1
G
/SYS/MB/CMP0/BR3/CH0/D1
J2501
3
H
Channel 1
/SYS/MB/CMP0/BR3/CH1/D0
J2601
2
G
/SYS/MB/CMP0/BR3/CH1/D1
J2701
3
H
* Upgrade path: DIMMs should be added with each group populated in the order shown.
† Fault replacement path: Each pair is addressed as a unit, and each pair must be identical.
TABLE 4-1
FB-DIMM Configuration
Branch Name
Channel Name
FRU Name
Motherboard FB-DIMM
Connector
FB-DIMM
Installation
Order
*
FB-DIMM
Pair
†
Содержание Netra T5220
Страница 1: ...Sun Netra T5220 Server Service Manual Part No E21359 02 January 2012...
Страница 14: ...1 4 Sun Netra T5220 Server Service Manual January 2012 FIGURE 1 1 Diagnostic Flowchart...
Страница 39: ...Chapter 1 Server Diagnostics 1 29 FIGURE 1 8 Flowchart of ALOM CMT CLI Variables for POST Configuration...
Страница 156: ...5 26 Sun Netra T5220 Server Service Manual January 2012...
Страница 171: ...Appendix A Signal Pinouts A 7...
Страница 172: ...A 8 Sun Netra T5220 Server Service Manual January 2012...