4-22
Sun Netra T5220 Server Service Manual • January 2012
FIGURE 4-14
FB-DIMM Upgrade Path
■
A replacement FB-DIMM must have the same part number as the other FB-DIMM
in its pair. For example, a replacement FB-DIMM in J1201 must have the same Sun
part number as the FB-DIMM in J1401, in order to ensure an identical pair.
■
If you are unable to obtain a matching FB-DIMM, you must replace both
FB-DIMMs in the pair.
TABLE 4-1
FB-DIMM Configuration
Branch Name
Channel Name
FRU Name
Motherboard FB-DIMM
Connector
FB-DIMM
Installation
Order
*
FB-DIMM
Pair
†
Branch 0
Channel 0
/SYS/MB/CMP0/BR0/CH0/D0
J1001
1
A
/SYS/MB/CMP0/BR0/CH0/D1
J1101
3
B
Channel 1
/SYS/MB/CMP0/BR0/CH1/D0
J1201
2
A
/SYS/MB/CMP0/BR0/CH1/D1
J1301
3
B