1-8
Sun Netra T5220 Server Service Manual • January 2012
1.2.1.3
Troubleshooting Memory Faults
If you suspect that the server has a memory problem, follow the flowchart
(
FIGURE 1-1
). Run the ALOM CMT compatability CLI (in ILOM)
showfaults
command, see
Section 1.4.1, “Using the ALOM CMT Compatibility CLI in ILOM” on
page 1-16
and
Section 1.4.4, “Displaying System Faults” on page 1-21
. The
showfaults
command lists memory faults and lists the specific FB-DIMMS that are
associated with the fault. Once you identify which FB-DIMMs to replace, see
Section 4.6, “Replacing FB-DIMMs” on page 4-23
for FB-DIMM replacement
instructions. You must perform the instructions in that chapter to clear the faults and
enable the replaced FB-DIMMs.
1.3
Using LEDs to Identify the State of
Devices
The server provides the following groups of LEDs:
■
Section 1.3.1, “Front and Rear Panel LEDs” on page 1-8
■
Section 1.3.2, “Hard Drive LEDs” on page 1-12
■
Section 1.3.3, “Power Supply LEDs” on page 1-12
■
Section 1.3.4, “Ethernet Port LEDs” on page 1-13
These LEDs provide a quick visual check of the state of the system.
1.3.1
Front and Rear Panel LEDs
The seven front panel LEDs (
FIGURE 1-2
) are located in the upper left corner of the
server chassis. Three of these LEDs are also provided on the rear panel (
FIGURE 1-3
).
Содержание Netra T5220
Страница 1: ...Sun Netra T5220 Server Service Manual Part No E21359 02 January 2012...
Страница 14: ...1 4 Sun Netra T5220 Server Service Manual January 2012 FIGURE 1 1 Diagnostic Flowchart...
Страница 39: ...Chapter 1 Server Diagnostics 1 29 FIGURE 1 8 Flowchart of ALOM CMT CLI Variables for POST Configuration...
Страница 156: ...5 26 Sun Netra T5220 Server Service Manual January 2012...
Страница 171: ...Appendix A Signal Pinouts A 7...
Страница 172: ...A 8 Sun Netra T5220 Server Service Manual January 2012...