40
Netra 240 Server Service Manual
• June
2004
Note –
By replacing the tie wrap, you ensure that the system configuration card is
properly seated in the card reader (see
). If the card projects out of the card
reader, the system does not boot properly. The tie wrap discourages accidental or
unintentional removal of the system configuration card.
3. Power on the server(s).
See
“Powering On the Server” on page
Caution –
Never remove the system configuration card while the server is booting
or running the Solaris software. Before removing or inserting the system
configuration card, either remove power from the server, or put it into Standby
mode.fs
Hard Drives
The Netra 240 server has slots for up to two internal hard drives. The slots accept
any Sun Low Voltage Differential (LVD) SCSI hard drive conforming to the 1-inch
SCA-2 form factor.
Note –
If a Netra 240 server uses one hard drive only, ensure that the filler panel is
fitted in the other hard drive bay. The server must not run without a filler in the
unoccupied hard drive bay. If you remove the hard drive slot filler panel, retain it for
future use.
Removing a Hard Drive
If you are removing a hard drive while the operating system is still running, you
must remove the drive logically from the operating system before physically
removing it from the server. If you are removing a hard drive from a server that is
powered off, skip to
in these procedures.
Use the following instructions in conjunction with the
cfgadm(M)
man page.
Содержание Netra 240
Страница 7: ...Contents vii Index 133...
Страница 8: ...viii Netra 240 Server Service Manual June 2004...
Страница 12: ...xii Netra 240 Server Service Manual June 2004...
Страница 70: ...52 Netra 240 Server Service Manual June 2004...
Страница 84: ...66 Netra 240 Server Service Manual June 2004...
Страница 120: ...102 Netra 240 Server Service Manual June 2004...
Страница 124: ...106 Netra 240 Server Service Manual June 2004...
Страница 132: ...114 Netra 240 Server Service Manual June 2004...