Chapter 2
Preparing to Service the System
19
FIGURE
2-3
Rotary Switch Positions
TABLE
2-2
Rotary Switch Positions and Server Behaviors
Rotary Switch Positions
Server Behavior
Normal
Normal operation
Diagnostics
Full POST during system boot
Locked
Disable On/Standby button
Write-protect ALOM Flash PROM
Write-protect OpenBoot PROM/POST Flash PROM
Disable suspension to OpenBoot PROM/kadb
i
i When the rotary switch is in the locked position, you cannot drop to OpenBoot PROM/kadb manually by is-
suing the
break
command.
Forced Standby
Force server into Standby mode
Disable on/standby button
Disable remote power control
Write-protect ALOM Flash PROM
Normal
Diagnostics
Locked
Forced
standby
Содержание Netra 240
Страница 7: ...Contents vii Index 133...
Страница 8: ...viii Netra 240 Server Service Manual June 2004...
Страница 12: ...xii Netra 240 Server Service Manual June 2004...
Страница 70: ...52 Netra 240 Server Service Manual June 2004...
Страница 84: ...66 Netra 240 Server Service Manual June 2004...
Страница 120: ...102 Netra 240 Server Service Manual June 2004...
Страница 124: ...106 Netra 240 Server Service Manual June 2004...
Страница 132: ...114 Netra 240 Server Service Manual June 2004...