82
Netra 240 Server Service Manual
• June
2004
3. Remove the server cover.
See
“Removing the Server Cover” on page
4. Open the rotating service module.
See
“Opening the Rotating Service Module” on page
5. Ensure that the server is properly grounded.
See
“Avoiding Electrostatic Discharge” on page
6. Disconnect the power distribution board wiring harness from the three connectors
on the system board (
).
FIGURE
5-8
Removing the Power Distribution Board
7. Disconnect the power distribution board cable from the SCSI interface board
(
).
Retaining
Wiring harness
screws
Содержание Netra 240