Chapter 6: Troubleshooting the Server
6-10
User Guide—Sun Cobalt LX50 Server
POST Beep Codes
The following tables list POST error beep codes. Prior to system video initialization, the BIOS and BMC use these
beep codes to notify users of error conditions.
Table 14.
BMC-Generated POST Beep Codes
Beep
Code
a
a. The code indicates the beep sequence; for example, 1-5-1-1 means a single
beep, then a pause, then 5 beeps in a row, then a pause, then a single beep, then
a pause, and then finally a single beep.
Description
1-5-1-1
FRB failure (processor failure)
1-5-2-1 Empty
Processor
1-5-2-2 No
Processor
1-5-4-2
Power fault: DC power unexpectedly lost (power control failures)
1-5-4-3
Chipset control failure
1-5-4-4
Power control failure
Table 15.
BIOS-Generated POST Beep Codes
Beep
Code
Error Message
Description
1
Refresh timer failure
The memory refresh circuitry on the Main Board is faulty.
2
Parity error
Parity can not be reset.
3
Base memory failure
Base memory test failure. See Table 16 on page 6-11 for additional error
details.
4
System timer
System timer is not operational.
5
Processor failure
Processor failure detected.
6 Keyboard
controller
Gate A20 failure
The keyboard controller may be bad. The BIOS cannot switch to protected
mode.
7 Processor
exception
interrupt error
The CPU generated an exception interrupt.
8
Display memory read/
write error
The system video adapter is either missing or its memory is faulty. This is not a
fatal error.
9
ROM checksum error
System BIOS ROM checksum error.
10
Shutdown register error
Shutdown CMOS register read/write error detected.
11
Invalid BIOS
General BIOS ROM error.
Содержание Cobalt LX50
Страница 1: ...Sun Cobalt LX50 Server User Guide...
Страница 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Страница 14: ...xiv User Guide Sun Cobalt LX50 Server...
Страница 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Страница 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Страница 79: ...Using the Service Partition Menu User Guide Sun Cobalt LX50 Server 4 21 Figure 58 Sample RESULT LOG continued...
Страница 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Страница 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...