Chapter 6: Troubleshooting the Server
6-4
User Guide—Sun Cobalt LX50 Server
Non-Critical Condition
A non-critical condition indicates that at least one of the following conditions is present:
•
Temperature, voltage, or fan non-critical threshold crossing.
•
Chassis intrusion.
•
Satellite controller sends a non-critical state, via the Set Fault Indication command, to the BMC.
•
A Set Fault Indication command from the system BIOS. The BIOS may use the Set Fault Indication command to
indicate additional, non-critical status such as system memory or CPU configuration changes.
Degraded Condition
A degraded condition indicates that at least one of the following conditions is present:
•
A processor is disabled by FRB or BIOS.
•
BIOS has disabled or mapped out some of the system memory.
Refer to the Sun Cobalt LX50 server Troubleshooting Guide for information on how to isolate the server component
responsible for any of the critical, non-critical or degraded conditions listed above.
Rear Panel Power Supply Status LED
The rear-panel power supply status LED is located as shown in Figure 82.
Figure 82.
Location of Rear-Panel Power Supply Status LED
The rear-panel power supply status LED has the states indicated in Table 11.
Other LEDs
There are several additional LEDs on the front and rear panels that indicate status and activity. See Chapter 3,
“Controls and Indicators,” for more details on these LEDs.
Table 11.
Power Supply Status LED States
Power Supply LED State
Power Supply Condition
OFF
No AC power present to power supply
BLINKING GREEN
AC power present, but only the standby outputs are on
GREEN
Power supply DC outputs on and OK
BLINKING AMBER
PSAlert# signal asserted, power supply on
AMBER
Power supply shutdown due to over current, over temperature, over voltage, or
undervoltage
AMBER or OFF
Power supply failed and AC fuse open or other critical failure
OM11668A
Power Supply Status LED
Содержание Cobalt LX50
Страница 1: ...Sun Cobalt LX50 Server User Guide...
Страница 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Страница 14: ...xiv User Guide Sun Cobalt LX50 Server...
Страница 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Страница 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Страница 79: ...Using the Service Partition Menu User Guide Sun Cobalt LX50 Server 4 21 Figure 58 Sample RESULT LOG continued...
Страница 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Страница 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...