Field Replaceable Unit (FRU) Procedures
User Guide—Sun Cobalt LX50 Server
5-23
Figure 77.
Installing the Heat Sink and Clip
9.
With the green heatsink clip lever in the upward position, center and push each black clip under the adjacent
processor socket anchor feature.
10. Slowly close the green clip lever as shown in Figure 78 until the clip lever (A) contacts tab (B).
Figure 78.
Closing the Locking Lever
11. Verify the heatsink clamp has latched correctly on each side.
✍
Note: The Comprehensive Test should be run after changing any FRU, CRU, or adding an
optional component. See “Run System Diagnostic Test” on page 4-15.
2
3
OM11708A
C
A
B
1
OM11709A
A
B