Chapter 5: Maintaining the Server
5-8
User Guide—Sun Cobalt LX50 Server
8.
Make sure that the rear of the power supply is fully seated on the chassis floor and in front of the raised
guides (C).
9.
Replace the chassis cover.
Hard Disk Drives
✍
Note
: The Comprehensive Test should be run after changing any FRU, CRU, or adding an
optional component. See “Run System Diagnostic Test” on page 4-15.
!
Caution:
Not all SCSI hard disk drives (HDD) are supported by the server. Unsupported drives
will not mate mechanically with the connector on the inside of the drive bay. All drives must be
LVDS SCA type (80-pin connector). The server does not support internal single-ended (SE)
drives.
Unless a RAID card is installed in the server, the hard drives cannot be hot swapped.
The use of unauthorized HDDs may damage the system and void the warranty. Only Sun-
certified drives should be used. See Table 4 on page 1-4 for a list of approved hard disk drives.
!
Caution:
To allow proper airflow and cooling during operation, all drive bays must contain a
HDD assembly (drive mounted on a carrier) or a carrier with an air baffle installed.
!
Caution:
You must remove power from the Sun Cobalt LX50 server before attempting to
remove or insert a HDD. Be sure to wait 30 seconds for the drive motor to come to a complete
stop before removing a drive.
Neither hot swap nor hot plug are supported on the server. Before replacing the HDD, you
must first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
Also be sure to back up any current data on your disk drive(s) before installing or reconfiguring
your disk environment.
!
Caution:
Put on the disposable ESD wrist strap supplied with each hard disk drive before
removing or installing a HDD.
!
Caution:
Special conditions apply when replacing a RAID drive
.
Make sure you are familiar
with Linux disk administration. Also be sure to back up any current data on your disk drive(s)
before installing or reconfiguring your disk environment.
✍
Note:
A third HDD can be inserted in place of the Floppy/CD-ROM combo unit under the
same restrictions of removing power as previously mentioned above.
Содержание Cobalt LX50
Страница 1: ...Sun Cobalt LX50 Server User Guide...
Страница 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Страница 14: ...xiv User Guide Sun Cobalt LX50 Server...
Страница 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Страница 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Страница 79: ...Using the Service Partition Menu User Guide Sun Cobalt LX50 Server 4 21 Figure 58 Sample RESULT LOG continued...
Страница 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Страница 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...