Field Replaceable Unit (FRU) Procedures
User Guide—Sun Cobalt LX50 Server
5-25
Figure 79.
Removing the Server Board
15. Slide the board toward the front of the chassis until the I/O connectors are clear of the chassis I/O openings.
16. Place the server board on an anti-static pad. You may use one of the two pads that are shipped with the new server
board.
17. Ensure that the Mylar insulator sheet is seated securely over the standoffs, is laying flat on the chassis floor, and
that the edge of the sheet is seated below the studs in the rear chassis wall.
18. Remove the replacement server board from its packaging and antistatic bag.
19. While placing the board on the chassis standoffs, carefully position the board I/O connectors in the rear chassis
I/O openings.
20. Adjust board position so that the two mounting holes near the board edges rest securely on the two-shouldered
standoffs.
21. Install the screws that you removed in step 14.
22. Install the power distribution board.
23. Install the SCSI backplane board.
24. Install the fan module.
25. Cable the new server board to the other system components.
26. Install the air baffle.
27. Install the power supply module.
✍
Note:
The server Main Board uses three holes to mount the board to the chassis stand-offs.
Each hole is designated with a white circle around it.
OM14479
Содержание Cobalt LX50
Страница 1: ...Sun Cobalt LX50 Server User Guide...
Страница 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Страница 14: ...xiv User Guide Sun Cobalt LX50 Server...
Страница 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Страница 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Страница 79: ...Using the Service Partition Menu User Guide Sun Cobalt LX50 Server 4 21 Figure 58 Sample RESULT LOG continued...
Страница 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Страница 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...