24
7 Related Parameters
7
Related Parameters
Parameters related to the use of the option are listed in
. Set these parameters as
needed for the application.
Table 5 Related Parameters
No.
Name
Unit
Description
Values
SF-520
HF-520
b1-01
Frequency
Reference
Selection 1
YES
YES
Selects the source of the frequency
reference.
0: LED operator - Digital preset speed d1-
01 to d1-17
1: Terminals - Analog input terminal A1
or A2
2: MEMOBUS/Modbus serial
communications
3: Option PCB
4: Pulse Input (Terminal RP)
Default: 1
Range: 0 to 4
b1-02
Run
Command
Selection 1
YES
YES
Selects the Run command input source.
0: LED operator - RUN and STOP keys
on the LED Operator Option
1: Digital input terminals S1 to S7
2: MEMOBUS/Modbus serial
communications
3: Option PCB
Default: 1
Range: 0 to 3
b1-15
Frequency
Reference 2
N/A
YES
Selects the frequency reference input
source.
0: LED operator - Digital preset speed d1-
01 to d1-17
1: Terminals - Analog input terminal A1
or A2
2: MEMOBUS/Modbus serial
communications
3: Option PCB
4: Pulse Input (Terminal RP)
Default: 0
Range: 0 to 4
b1-16
Run
Command
Source 2
N/A
YES
Selects the Run command input source.
0: LED operator - RUN and STOP keys
on the LED Operator Option
1: Digital input terminals S1 to S7
2: MEMOBUS/Modbus serial
communications
3: Option PCB
Default: 0
Range: 0 to 3