8 Option Fault Diagnostics
28
LED Operator
(JVOP-182-H)
LED Operator
(HF-520 and SF-520
built-in)
Description
LED Operator Option Connection Fault
Data should appear on the LED operator built in the unit. By
reconnecting the option to the unit, data should also appear on the
option display.
An oPr fault will occur when both of the following conditions are
true:
Output is interrupted when the option is disconnected (o2-06 = 1).
The Run command is assigned to the option (b1-02/b1-16= 0 and
LOCAL is selected).
Cause
Possible Solution
Option is not properly connected to the unit.
• Check the connection between the option and the unit.
• Replace the cable if damaged.
• Turn off the unit input power and disconnect the option.
Reconnect the option and reapply unit input power.
<1> Display will vary depending on operation status.