4  Option Components

 

 13

Keys

Refer to 

Figure 2

 and 

Table 3

 for details on key names and functions.

Figure 2  

Figure 2  Keys

Table 3  Key Names and Functions

No.

Key

Name

Function

1

ESC  Key

• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the following display: 

Drive: Frequency Reference
Converter: DC Bus Voltage Reference
Regenerative unit: DC Bus Voltage

2

RESET Key

• Moves the cursor to the right.
• Resets the unit to clear a fault situation.

3

RUN Key

Starts the unit and motor.

4

Up Arrow Key

Scrolls up to display the next item, selects parameter numbers and 
increments setting values.

ALM

REV

DRV

FOUT

LO

RE

ESC

RUN

STOP

ENTER

RESET

DIGITAL OPERATOR JVOP-182

1

2

3

4 5

6

9

14 13 12

10

8

11

7

R

RU

UN

Содержание JVOP-182-H

Страница 1: ...n Manual Type JVOP 182 H NOTICE 1 Make sure that this installation manual is dellvered to the end user of inverter unit 2 Read this manual before installing or operating the inverter unit and store it...

Страница 2: ...patent liability is assumed with respect to the use of the information contained herein Moreover because Sumitomo is constantly striving to improve its high quality products the information contained...

Страница 3: ...1 PREFACE AND SAFETY 4 2 PRODUCT OVERVIEW 9 3 RECEIVING 10 4 OPTION COMPONENTS 12 5 INSTALLATION PROCEDURE 17 6 BASIC OPERATION 22 7 RELATED PARAMETERS 24 8 OPTION FAULT DIAGNOSTICS 27 9 SPECIFICATION...

Страница 4: ...tion all controls should be designed to detect faults dynamically and fail safely under all circumstances All systems or equipment designed to incorporate a product manufactured by Sumitomo must be su...

Страница 5: ...e Technical Manual Manual No DM2203E The Technical Manual is packaged with the RS 232C Interface Option and contains a basic overview of wiring settings functions and fault diagnoses Inverter Operatin...

Страница 6: ...cording to this manual and local codes The following conventions are used to indicate safety messages in this manual Failure to heed these messages could result in serious or fatal injury or damage to...

Страница 7: ...ng any devices The option board should be used according to the instructions described in this manual Any illustrations photographs or examples used in this manual are provided as examples only and ma...

Страница 8: ...to halogen group disinfectants Failure to comply may cause damage to the electrical components in the option Do not pack the unit in wooden materials that have been fumigated or sterilized Do not ster...

Страница 9: ...e unit to perform these tasks Read or modify unit parameters Read and copy unit parameter settings to another Sumitomo unit Operate the unit Monitor unit operation status All keys except for the STOP...

Страница 10: ...er printed on the Name plate of the option If you have received the wrong model or the option does not function properly contact your supplier Contents and Packaging Table 1 Contents of Package Parts...

Страница 11: ...drive sold separately 2 To connect the option to SF 520 install the RS 232C Interface Option to the unit Yaskawa Part Number Notes Page RS 232C Interface Option SI 232 J H 2 21 Digital Operator Cable...

Страница 12: ...4 Option Components 4 Option Components Option Figure 1 Figure 1 Option Components A Data Display Area D Installation Mounting Holes B LED Indicators E Communication Cable Connector C Keys B A C D E...

Страница 13: ...button will return to the following display Drive Frequency Reference Converter DC Bus Voltage Reference Regenerative unit DC Bus Voltage 2 RESET Key Moves the cursor to the right Resets the unit to c...

Страница 14: ...ommand and frequency reference Note The LOCAL REMOTE key is only effective when the unit is stopped in Drive Mode As a safety precaution it is possible to disable the LO RE Selection Key by setting pa...

Страница 15: ...equency reference control LOCAL When a device other than the option is selected for Run command and frequency reference control REMOTE During run During deceleration to stop When a Run command is inpu...

Страница 16: ...oPE detected Normal state no fault or alarm Motor is rotating in reverse Motor is rotating forward Drive Mode Programming Mode Displays output frequency Hz As illustrated in this manual ALM REV DRV F...

Страница 17: ...or recommended cables Failure to comply may cause the unit or option to function incorrectly Properly connect the connectors Failure to comply may prevent proper operation and possibly damage equipme...

Страница 18: ...ions 1 Use only Sumitomo cables or cables recommended by Sumitomo Refer to Item Names and Part Numbers Sold Separately on page 11 90 3 54 78 3 07 60 2 36 7 9 0 31 minimum 50 1 97 Unit mm in 12 2 0 48...

Страница 19: ...e startup as the cover will reduce ventilation and cause the unit to overheat 1 Cut an opening in the enclosure panel for the option according to Figure 6 2 Position the option so the LED display face...

Страница 20: ...d cables Using a cable not specified may cause the option or drive to malfunction Note The STOP key on the built in LED operator of the drive is the only functional key on the drive when the option is...

Страница 21: ...commended cables Using a cable not specified may cause the option or drive to malfunction Note The STOP key on the built in LED operator of the drive is the only functional key on the drive when the o...

Страница 22: ...estimated 100 000 times Copy Copies parameter settings from the option to another Sumitomo unit These parameters control the Copy function of the digital operator The Copy function stores parameter se...

Страница 23: ...ult 1 Turn on the power to the unit The initial display appears 2 Press to select the Parameter Setting and Press 3 Press to select o3 01 Copy Function Selection and press 4 Press to select 01 5 Press...

Страница 24: ...lection 1 YES YES Selects the Run command input source 0 LED operator RUN and STOP keys on the LED Operator Option 1 Digital input terminals S1 to S7 2 MEMOBUS Modbus serial communications 3 Option PC...

Страница 25: ...t operator 0 Disabled 1 Enabled Default 1 Range 0 1 o2 05 Frequency Reference Setting Method Selection YES YES Selects if the ENTER key press is required when inputting the frequency reference by the...

Страница 26: ...rameter settings in the drive converter or regenerative unit are compared to those in the LED Operator Option Note When using the copy function the drive model number o2 04 software number U1 14 and c...

Страница 27: ...LED Operator HF 520 and SF 520 built in Description 1 LED Operator JVOP 182 H Communication Error 1 Occurs when the unit cannot communicate with the option within 5 seconds after the power is switched...

Страница 28: ...l occur when both of the following conditions are true Output is interrupted when the option is disconnected o2 06 1 The Run command is assigned to the option b1 02 b1 16 0 and LOCAL is selected Cause...

Страница 29: ...Temperature 10 to 50 C 14 to 122 F Humidity up to 95 RH no condensation Storage Temperature 20 to 60 C 4 to 140 F allowed for short term transport of the product Area of Use Indoor free of corrosive...

Страница 30: ...at is caused by 1 Installation connection combination or integration of the Product in or to the other equipment or machine that rendered by any person or entity other than the Seller 2 Insufficient m...

Страница 31: ...No DM2307E 1 Printed 2014 06...

Отзывы: