OnAir 2500/OnAir 3000 Digital Mixing Consoles
6-26 Con
fi
guration
Date printed: 21.01.09
SW V3.0
6.5.15 System Time
On this page, all settings for operation with the internal real-time clock or an
external time reference signal are made.
Time Sync Ref
The type of external time reference signal can be selected here from:
None
,
MONITORA
(time information according to the Monitora protocol, e.g. from
a Studer DigiMedia CAB system),
Ext.Time Sync*
, or
NTP
(if the console
has access to an internet time server over a network). If
None
is selected, the
console operates on its own, internal real-time clock.
OnAir 2500:
The External Time Sync card is not supported byOnAir 2500.
*
The
Ext. Time Sync
button is displayed only if an optional Time Sync Card
is installed and connected to a time receiver; selection of the input signal for-
mat is performed with DIP switches on the card (
refer to OnAir 3000 service
instructions, chapter 3
).
NTP Time Server
If
NTP
has been selected above, the NTP time server’s web address is set
here. When touching this button, a keyboard appears for entering the address.
Proceed according to the corresponding paragraph in
chapter 6.5.1
.
For SW V3.0 and up, IP addresses are supported for defining the NTP time
server as well.
Time Zone
Enter your local time zone here. In the example above, the “(GMT +01:00)
Amsterdam/Berlin/Bern/Rome/Stockholm/Vienna” time zone is selected.
Automatic Daylight Saving
Automatic daylight saving time for the internal watch is be activated here,
according to the selected time zone; this is regardless of the current external
time sync reference.
Содержание OnAir 3000
Страница 1: ...Studer OnAir 3000 Digital Mixing Console SW Version 3 0 Operating Instructions ...
Страница 16: ...Date printed 18 01 08 SW V2 0 OnAir 3000 Digital Mixing Console Important ...
Страница 30: ...OnAir 3000 Digital Mixing Console 1 8 Introduction Date printed 31 10 08 SW V3 0 ...
Страница 40: ...OnAir 3000 Digital Mixing Console 3 6 Operating Concept Date printed 31 10 08 SW V3 0 ...
Страница 168: ...OnAir 3000 Digital Mixing Console 5 116 Operation Date printed 31 10 08 SW V3 0 ...
Страница 274: ...OnAir 3000 Digital Mixing Console 7 14 A B Desk Configuration Date printed 31 10 08 SW V3 0 ...
Страница 287: ...Studer D21m I O System Components Product Information March 2009 13th Edition ...