Each of these system messages is also entered to the Log List. In order to be
removed from the Log List, it has to be acknowledged by the user.
To prevent the user from being annoyed with lots of warning and error mes-
sage dialog boxes, these are generated only where it is impossible to notice
function execution failure. In these cases an error message is generated if the
function execution fails completely. A warning is given to the user if a func-
tion might be executed partially only.
5.12.3 Error Messages
5.12.3.1 System
Error Code
Error Type
Error Text / Remarks
1000
ERROR
SYSTEM, Fatal software error occurred - System will be stopped. For details see log-file.
1001
WARNING
SYSTEM, Extension
‘TalkBack.ext’
could not be started. Reason:
‘Did not find XML-File or XDR-File:
xml\TalkBack.xml’.
1002
WARNING
SYSTEM, Extension
‘UserGUI.ext’
could not load User Buttons. Reason:
‘Did not find XML-File or XDR-
File: xml\TalkBack.xml’.
1100
ERROR
SYSTEM,
‘Desk’
communication failure: Connection to
‘System40:Core’
lost.
The error appears if a container loses the network connection to another container under the following
conditions:
a) the remote container is within the same system
b) the container depends on the remote container (proxy objects exist)
c) the container itself is not a Core (from the user point of view, a Core doesn’t depend on any other
container, even if there exist proxy objects)
1200
WARNING
SYSTEM, Number of
‘Logical Inputs’
has been truncated to
‘128’
1201
WARNING
SYSTEM, Low Memory on
‘System40:Core’.
Physical Memory available:
4.802
MB
Process Memory available:
7.802
MB.
Appears during power-up or runtime, when the physical memory or the process memory falls below 5 MB.
1300
WARNING
SYSTEM, The console set-up cannot be changed, since there is at least one channel on-air. Please make
sure no channel is on-air and try again.
Appears when trying to switch to another console set-up while a LogicalInput is on-master (FInputStatus ->
ChannelOnMaster).
1301
WARNING
SYSTEM, The console set-up cannot be changed, since there is at least one remote channel (I/O sharing)
on-air. Please make sure no channel is on-air on a remote system and try again.
Appears when trying to switch to another console set-up, while a NetLogicalInput of another system is
consuming a LogicalInput and is on-master (FInputStatus -> ChannelOnMasterNet).
1302
WARNING
SYSTEM, Please restart the whole Mixing Console to complete the set-up change.
Appears when switching to another console set-up.
Содержание OnAir 3000
Страница 1: ...Studer OnAir 3000 Digital Mixing Console SW Version 3 0 Operating Instructions ...
Страница 16: ...Date printed 18 01 08 SW V2 0 OnAir 3000 Digital Mixing Console Important ...
Страница 30: ...OnAir 3000 Digital Mixing Console 1 8 Introduction Date printed 31 10 08 SW V3 0 ...
Страница 40: ...OnAir 3000 Digital Mixing Console 3 6 Operating Concept Date printed 31 10 08 SW V3 0 ...
Страница 168: ...OnAir 3000 Digital Mixing Console 5 116 Operation Date printed 31 10 08 SW V3 0 ...
Страница 274: ...OnAir 3000 Digital Mixing Console 7 14 A B Desk Configuration Date printed 31 10 08 SW V3 0 ...
Страница 287: ...Studer D21m I O System Components Product Information March 2009 13th Edition ...