OnAir 3000 Digital Mixing Console
5-110 Operation
Date printed: 31.10.08
SW V3.0
5.12.3.3 I/O 21
Error Code
Error Type
Error Text / Remarks
3001
INFO
I/O 21, Rack
‘Int’
: Reconfiguration required.
Appears if a new card has been added.
3002
INFO
I/O 21, The Rack
‘Ext 1’
was reconfigured. Please make sure the Core is rebooted in order to achieve
system consistency.
3003
WARNING
I/O 21, Slot change: Card from Slot
‘2’
of the rack
‘Internal’
removed.
3004
INFO
I/O 21, Slot change: Same Card in Slot
‘2’
of the rack
‘External 1’
re-installed.
3005
INFO
I/O 21, Slot failure: The Card in Slot 13 must be a GPIO Card.
3006
INFO
I/O 21, Slot change: Card to Slot
‘2’
added. Please reconfigure the rack
‘Internal’
and reboot the Core in
order to achieve system consistency.
3007
WARNING
I/O 21, Slot failure: Unknown Card found. Card in Slot
‘3’
of the rack
‘D21m Rack 1’
not supported.
3008
WARNING
I/O 21, Secondary power failure: Digital Power. (Rack
‘External 2’
)
3009
WARNING
I/O 21, Secondary power failure: Analog Power. (Rack
‘External 2’
)
3010
WARNING
I/O 21, Primary Power Supply 1 fail. (Rack
‘External 1’
)
3011
WARNING
I/O 21, Primary Power Supply 2 fail. (Rack
‘Internal’
)
3013
WARNING
I/O 21, Couldn’t open the COM port.
3014
ERROR
I/O 21, Missing D21m rack
‘External 1’
.
3015
ERROR
I/O 21, Communication Protocol to D21m not supported.
Appears after power-up if an earlier HD card (or firmware) is installed (.410.23 instead of .412.20).
3016
WARNING
I/O 21, Communication to rack
‘Internal’
lost.
3018
INFO
I/O 21, Invalid module on merger port 13
3019
WARNING
I/O 21, No Communication to the internal D21m.
3020
INFO
I/O 21, Not configured D21m rack on port
‘10’
found. Check XML configuration.
3021
INFO
I/O 21, The card in slot
‘2’
of the rack
‘External 3’
is not allowed in this slot.
Appears during power-up if a Mic/Line In card or an other double-width card is detected in an even slot
(e.g. slot 2 instead of slot 1).
3022
INFO
I/O 21, Additional HD Link to a DSP card required. Rack
‘Int’
provides
‘128’
Inputs, but only
‘96’
channels
are connected to the Core.
‘32’
inputs not available.
Appears during power-up if not enough HD link channels to the DSP cards are available. E.g. there are 3
MADI cards (3*64 channels), but only one HD link (with 96 channels).
3023
INFO
I/O 21, Additional HD Link to a DSP card required. Rack ‘Int’ provides
‘128’
outputs, but only
‘96’
channels
are connected to the Core.
‘32’
outputs not available.
Appears during power-up if not enough HD link channels to the DSP cards are available. E.g. there are 3
MADI cards (3*64 channels), but only one HD link (with 96 channels).
3024
INFO
I/O 21, MADI card in slot
‘3’
of the rack
‘Int’
switched to redundant interface. AUX interface is active.
Appears during runtime (NOT during power-up) if the MADI card is switched from AUX to MAIN interface or
vice versa.
3025
WARNING
I/O 21, MADI card in slot 3 of rack
‘Int’
: Neither MAIN nor AUX interface is active.
Appears during runtime (NOT during power-up) if neither MAIN nor AUX interface of the MADI card could
lock.
3026
INFO
I/O 21, Not enough MADI channels from StageBox
‘StageBox1’
to Rack
‘Int’
. Provides
‘80’
inputs, but
only
‘64’
channels are available.
‘16’
inputs not available.
Appears during power-up if not enough MADI channels are available to the master D21m cards. E.g. there
are 5 AES cards (5*16 channels), but only one MADI link (with 64 channels).
3027
INFO
I/O 21, Not enough MADI channels from StageBox
‘StageBox1’
to Rack
‘Int’
. Provides
‘80’
outputs, but
only
‘64’
channels are available.
‘16’
outputs not available.
Appears during power-up if not enough MADI channels are available to the master D21m cards. E.g. there
are 5 AES cards (5*16 channels), but only one MADI link (with 64 channels).
3030
WARNING
I/O 21, HD Card unlock. Missing HD Link input signal. (Rack
‘External 2’
)
Appears during power-up or runtime if the HD card cannot lock.
3031
INFO
I/O 21, HD Card lock. HD Link input signal available. (Rack
‘External 2’
)
Appears only during runtime if the HD card is locked again after the HD Link input signal was missing.
continued...
Содержание OnAir 3000
Страница 1: ...Studer OnAir 3000 Digital Mixing Console SW Version 3 0 Operating Instructions ...
Страница 16: ...Date printed 18 01 08 SW V2 0 OnAir 3000 Digital Mixing Console Important ...
Страница 30: ...OnAir 3000 Digital Mixing Console 1 8 Introduction Date printed 31 10 08 SW V3 0 ...
Страница 40: ...OnAir 3000 Digital Mixing Console 3 6 Operating Concept Date printed 31 10 08 SW V3 0 ...
Страница 168: ...OnAir 3000 Digital Mixing Console 5 116 Operation Date printed 31 10 08 SW V3 0 ...
Страница 274: ...OnAir 3000 Digital Mixing Console 7 14 A B Desk Configuration Date printed 31 10 08 SW V3 0 ...
Страница 287: ...Studer D21m I O System Components Product Information March 2009 13th Edition ...