Before putting into operation, the system must be checked for internal for-
mation of condensation or ice. Only with a minute formation of ice, direct
evaporation (sublimation) may be expected; otherwise the system must be
heated and dried while switched off.
A system without visible internal formation of ice or condensation should
be heated up with its own heat dissipation, as homogeneously (and subse-
quently as slow) as possible; the ambient temperature should then always
be lower than the one of the outgoing air.
If it is absolutely necessary to operate the cold system immediately within
warm ambient air, this air must be dehydrated. In such a case, the absolute
humidity must be so low that the relative humidity, related to the coldest
system surface, always remains below 100%.
Ensure that the enclosed air is as dry as possible when powering off (i.e.
before switching off in winter, aerate the room with cold, dry air, and re-
move humid objects as clothes from the room).
These relationships are visible from the following climatogram. For a con-
trolled procedure, thermometer and hygrometer as well as a thermometer
within the system will be required.
Example
1:
An OB-van having an internal temperature of 20 °C and relative humidity
of 40% is switched off in the evening. If temperature falls below +5 °C,
dew or ice will be forming.
Example
2:
An OB-van is heated up in the morning with air of 20 °C and a relative
humidity of 40%. On all parts being cooler than +5 °C, dew or ice will be
forming.
Содержание OnAir 3000
Страница 1: ...Studer OnAir 3000 Digital Mixing Console SW Version 3 0 Operating Instructions ...
Страница 16: ...Date printed 18 01 08 SW V2 0 OnAir 3000 Digital Mixing Console Important ...
Страница 30: ...OnAir 3000 Digital Mixing Console 1 8 Introduction Date printed 31 10 08 SW V3 0 ...
Страница 40: ...OnAir 3000 Digital Mixing Console 3 6 Operating Concept Date printed 31 10 08 SW V3 0 ...
Страница 168: ...OnAir 3000 Digital Mixing Console 5 116 Operation Date printed 31 10 08 SW V3 0 ...
Страница 274: ...OnAir 3000 Digital Mixing Console 7 14 A B Desk Configuration Date printed 31 10 08 SW V3 0 ...
Страница 287: ...Studer D21m I O System Components Product Information March 2009 13th Edition ...