43
Connect the room controller cables to the main Siemens RVS21.826 controller on the bottom input rail, terminals 5,6
& 7 under X86 (G+, CL-, CL+). Located below by the arrow.
Once the wiring has been completed, insert the top of the user interface / room controller into the top of the mounting
frame. Once inserted, lower the controller towards the mounting frame until you feel and hear it click.
17.4.4
U
NINSTALL
U
SER
I
NTERFACE
/
R
OOM
C
ONTROLLER
1. Place a screwdriver from below into the moveable snappers of the
controller.
2. Press the snap and simultaneously lift the housing top. The housing
remains in place at the top.
3. Unhinge the housing top at the top.
4. The housing top is now separated from the housing base.