INSTaLLaTION
Specification
www.stiebel-eltron.com
WPL 15 IKS | WPL 25 IK |
71
17.4 External unit wiring diagram WPL 15 IKS-2 and WPL 25 IK-2
A1
X1
X2
X3
X4
X5
X1
X2
X3
X4
X5
X6
M8
M
__
B14 (T3)
1
2
3
1
2
3
L
N
1
2
3
1
2
3
+
-
G
1
2
Tacho in
+10V in
M6
M
1~
5
6
B13 (T2)
3
4
B12 (T1)
1
2
1
2
3
4
5
6
1
2
3
L
N
3
4
PWM out
GND
1
2
3
4
> T
N3
L
N
X8
X7
X9
Z11
Z12
Z12
Z12
Das Entstörglied Z12 umfasst die
drei markierten Kabel
85
�03
�1
1�
00
04
A1 RCC refrigerant circuit controller
A1/X1
Power supply
A1/X2
Expansion valve connection
A1/X3
Temperature sensors
A1/X4
Fan control
A1/X5
Modbus
B12(T1) Defrost temperature sensor (T1)
B13(T2) Outside temperature sensor (T2)
B14(T3) Evaporator outlet temperature sensor (T3)
M6 Fan
M8 Expansion valve
N3 Ribbon heater temperature switch
X1 Mains terminal
X2 Mains terminal, fan
X3 Modbus terminal, outdoor
X4 Terminal, ribbon heater
X5 Terminal, fan control
X6 Earth screw
X7 Earth screw, control panel cover
X8 Push-on earthing terminals, pipes