The controller is supplied with power via a power supply
cable. The power supply of the device must be 100 ... 240V~
(50 ... 60 Hz).
The controller is equipped with 4 relays in total to which
loads such as a pump, a valve, etc. can be connected:
• Relays R1 ... R3 are semiconductor relays, designed for
pump speed control
Conductor R1... R3
Neutral conductor N
Ground terminal
• Relay 4 is a standard relay
Conductor R4
Neutral conductor N
Ground terminal
Depending on the product version, power supply cable and
sensor cables are already connected to the device. If that is
not the case, please proceed as follows:
Connect the temperature sensors (S1 to S5) to the
corresponding terminals with either polarity:
S1 = sensor 1 (collector sensor )
S2 = sensor 2 (e. g. tank sensor bottom)
S3 = sensor 3 (e. g. tank sensor top)
S4 = sensor 4 (e. g. tank sensor tank 2)
S5 = sensor 5 (e. g. collector sensor collector 2)
Connect the grundfos sensors to the VFS and RPS inputs.
A V40 flowmeter can be connected to the terminals V40
and GND (either polarity).
The terminals marked “PWM” are control outputs for a
high-efficiency pump (PWM1 is allocated to R1 and PWM2
is allocated to R2).
The power supply connection is at the terminals:
Neutral conductor N
Conductor L
Conductor L' (L' is not connected with the power supply
cable. L' is a fused contact permanently carrying voltage)
Ground terminal
WARnIng!
electric shock!
Upon opening the housing, live parts
are exposed.
Î
Always disconnect the control-
ler from power supply before
opening the housing!
WARnIng!
electric shock!
L' is a fused contact permanently
carrying voltage
Î
Always disconnect the control-
ler from power supply before
opening the housing!
note:
Connecting the device to the power supply must
always be the last step of the installation!
note:
For more details about the initial commissioning
procedure, see chap. 5, page 73.
note:
The connection depends on the system selected,
see chap. 2.6. “System layouts”