© Stiebel 11091_SOM_9s.mon
us.ind
d
| 38
SOM 9s
Adjustment channels
Channel
Sub channel 1
Sub channel 2 Factory
setting
Change to
Description
Page
LOAD2 >
Loading 2
DT2O
12 °R
Switch-on temperature difference 2
78
DT2F
8 °R
Switch-off temperature difference 2
78
DT2S
20 °R
Set temperature difference 2
78
RIS2
4 °R
Rise 2
78
S2MAX
140 °F
Tank maximum limitation 2
78
LST2
ON
Loading tank 2
79
COL >
Collector
CEM
270 °F
Collector emergency temperature
80
OCCO**
OFF
Option collector cooling
80
CMAX
230 °F
Maximum collector temperature
80
OCMI
OFF
Option collector minimum limitation
80
CMIN
50 °F
Minimum collector temperature
80
OTCO
OFF
Option evacuated evacuated tube collector
function
81
TCST
07:00
Evacuated evacuated tube collector starting time 81
TCEN
19:00
Evacuated evacuated tube collector ending time
81
TCRU
30 s
Evacuated evacuated tube collector runtime
81
TCIN
30 min
Evacuated tube collector standstill interval
81
OCFR
OFF
Option collector frost protection
82
CFR O
40 °F
Antifreeze temperature collector on
82
CFR F
42 °F
Antifreeze temperature collector off
82
LLOGI >
Loading logic
PRIO
Priority logic
82
PRIO
2
Priority logic
82
OSTS
OFF
Tank set option
83
TST1
120 °F
Set tank temperature tank 1
83
TST2
120 °F
Set tank temperature tank 2
83
tLB
2 min
Loading break time
82
tRUN
15 min
Circulation runtime
82
PSPEE
OFF
Pause speed option
83
PDELA
OFF
Pump delay option
83
OOVRU*
OFF
Overrun option
84
COOL >
Cooling functions
OSYC**
OFF
System cooling
85
OSTC
OFF
Tank cooling
85
OHDP**
OFF
Heat dump
85
DT3 >
Return preheating
DT3O
12 °R
Switch-on difference
86
DT3F
8 °R
Switch-off difference
86
S2DT3
3
Reference sensor heat source
87
AH >
Backup heating option
AH O
110 °F
Backup heating switch-on temperature
87
AH F
120 °F
Backup heating switch-off temperature
87
t1O
06:00
Switch-on time 1
88
t1F
22:00
Switch-off time 1
88
t2O
00:00
Switch-on time 2
88
t2F
00:00
Switch-off time 2
88
t3O
00:00
Switch-on time 3
88
t3F
00:00
Switch-off time 3
88
PUMP >
Pump speed
PUMP1
OnOF
Speed variant pump 1
79
PUMP2
OnOF
Speed variant pump 2
79
PUMP3
OnOF
Speed variant pump 3
79
MAN >
Manual mode
MAN1
Auto
Manual mode 1
88
MAN2
Auto
Manual mode 2
88
MAN3
Auto
Manual mode 3
88
MAN4
Auto
Manual mode 4
88
BLPR >
OFF
Blocking protection
88
OTDIS >
OFF
Thermal disinfection option
89
OPARR>
OFF
Parallel relay option
90