Internal installation WPL 13/18/23 E/cool
1
Condensate drain
2
Heating flow
3
Heating return
4
Control panel
5
Air vent valve
6
High limit safety cut-out
DHC cartridge 3D-C
Internal installation WPL 13/18/23 E/cool
1
Heat pump
2
impact sound insulation
3
Floating screed
screed and impact sound
insulation. recess
if provided.
Internal installation WPL 13/18/23 E/cool
Dimensions in mm
Air routing with hoses
the total length of hoses on the air
inlet and discharge side must not
exceed 8 m. never incorporate more
than four 90° bends.
the hose will tend to sag because of
its flexibility; therefore secure it in
approx. 1 m intervals. special hoses
are used to route the inlet air from
the outside to the heat pump and
expelled air from the heat pump
to the outdoors. these hoses are
highly flexible, thermally insulated
and are self-extinguishing in case of
fire. thermally insulated hoses are
available in 3 m and 4 m lengths
(li Ø 560 mm).
Air routing with air ducts
with air routes longer than 8 m,
air ducts can also be connected to
the heat pump. the cross-section of
the air duct varies according to the
air flow rate and according to the
externally prevailing, static pressure
differential of the heat pump. to
reduce the transfer of structure-borne
noise in the building, install an air
hose or canvas flange between the
heat pump and air ducts. when sizing
air ducts and grilles, observe the
external pressure of the fan.
Special features
if the heat pump is installed in
an enclosed room, containing a
combustion appliance that takes
its combustion air directly from
the room (open flue operation),
then a ventilation aperture to the
installation location with 250 cm²
diameter is required, to prevent the
heat pump from influencing the
operation of the gas or oil burner.
without this additional ventilation,
small, unavoidable leakages on the
air inlet side, e.g. at hose connectors
or at the heat pump, will reduce the
air pressure in the enclosed room to
unacceptable levels.
IntErnal InStallatIon wpl 13/18/23 E/cool
Содержание Heat pumps
Страница 97: ...97 www stiebel eltron COM Notes ...
Страница 110: ...110 www stiebel eltron COM Notes ...
Страница 116: ...116 www stiebel eltron COM Notes ...
Страница 124: ...124 www stiebel eltron COM Notes ...
Страница 182: ...182 www stiebel eltron COM Notes ...
Страница 183: ...183 www stiebel eltron COM Accessories for heating heat pumps ...
Страница 234: ...234 www stiebel eltron COM WPF E mono mode without buffer cylinder WPF E mono mode with DHW heating ...
Страница 235: ...235 www stiebel eltron COM WPF E mono mode with low loss header WPF E mono mode with DHW heating and low loss header ...
Страница 247: ...247 www stiebel eltron COM DHW heat pumps ...