![STIEBEL ELTRON Heat pumps Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/stiebel-eltron/heat-pumps/heat-pumps_technical-manual_1376699058.webp)
58
www.stiebel-eltron.CoM
Condensate drain
the condensate drain hose must be
routed with a slope downwards or to
the side out of the heat pump. when
installing the heat pump outside,
route the condensate to an existing
drain or into a coarse gravel soak
away. For this, ensure an installation
that is free from the risk of frost.
conDensate connection
Concrete slab, approx. 10 cm
Gravel layer, approx. 30 cm
Condensate drain
approx. 120 cm
Condensate drain