120
www.stiebel-eltron.CoM
Geothermal probe heat pump system
InStallatIon, gEotHErmal probE
Pe pipe for the geothermal probe:
Pe-HD 25 x 2.3 Pn 10 (Dn 20)
Probe depth:
Dn 20 up to 60 m, Dn 25 up to 100 m
Probe spacing:
5.0 m
expansion vessel for geothermal probes:
brine resistant with 0.5 bar pre-charge pressure
Mixture for filling geothermal probes:
33% by vol. ethylene glycol (tyfocor), 67% by vol. water
system fill pressure:
2.0 bar
boiler room
Heating
circuit
Probe 1
Duct incl.
distribution
Probe 2