EN
G
LI
SH
WWW.stieBel-eltron.com
acW Basic |
41
installation
assemBly
10. assembly
10.1 assembly location
When selecting the installation location, observe the critical en-
vironmental factors that influence the use of wall mounted air
conditioning appliances.
critical environmental factor
problem
examples
application
Air containing some or a lot of dust
Heat exchanger and poss. siphon
become blocked.
-
Factories producing cement, lime or
gypsum
-
Warehouses
-
Hairdressing salons
-
usage of air conditioning appliances not
permissible
-
usage only possible with reduced
maintenance intervals
-
usage only possible with reduced
maintenance intervals
Below the room temperature limits of ap-
prox. 20 °C
Heat exchanger ices up.
-
Wine cellar
-
Cold food store
-
Flower shops
-
using air conditioning appliances is not
permissible
-
using air conditioning appliances is not
permissible
-
using air conditioning appliances is not
permissible
Atmosphere containing ammonia
Heat exchanger corrodes
-
Sewage works
-
If handling faeces
-
using air conditioning appliances is not
permissible
-
using air conditioning appliances is not
permissible
Environments with oil fog
Heat exchanger becomes clogged.
-
Machinery rooms
(lathe or milling work)
-
usage only possible with reduced
maintenance intervals
As heating or for frost protection
Defrost process cannot be ensured
-
Winter gardens
-
Portakabins
-
using air conditioning appliances is not
permissible
Exception:
As central heating backup, e.g. winter
garden with underfloor heating
The maintenance intervals for this appliance series are given in
the chapter „Maintenance“.
10.2 Handling
f
Observe the handling symbols on the packaging.
f
Never transport appliances that have already been unpacked
through heavy rain or rooms full of dust from construction
work, for example.
10.3 assembly
The appliance can be mounted on the wall. However, this should
not be done during the initial building works.
!
Risk of damage
Ensure that the wall and fixing parts used have sufficient
load-bearing capacity to be able to support the weight
of the appliance.
Furthermore please note:
- Install the internal appliance in a location where optimum air
distribution is ensured. Never let the air flow be hindered by
large objects.
- Never position the appliance in direct proximity of seats or
work areas, to avoid creating a disruptive air flow.
- Only mount the internal appliances on a solid wall.