Applications
RFI-9256 Radio Modem User Manual
Page 42 of 109
6. Applications
6.1 Basic Point-to-point Network
A basic point to point network is shown in Figure 14.
RFI-9256
Master
RFI-9256
Slave
Main
DT
E
Main
DT
E
RADIO CONFIGURATION
Unit is a SLAVE
Network Address: 12
Hopping Pattern: 4
Rx Address: 2000
PROTOCOL CONFIGURATION
Main Port: Point-to-point to 1000
SERIAL CONFIGURATION
Main Port: 115200, 8N1, Hardware Flow
RADIO CONFIGURATION
Unit is a MASTER
Network Address: 12
Hopping Pattern: 4
Rx Address: 1000
PROTOCOL CONFIGURATION
Main Port: Point-to-point to 2000
SERIAL CONFIGURATION
Main Port: 115200, 8N1, Hardware Flow
Figure 14: Basic point-to-point network
A single master unit and a single slave unit are configured such that:
The have the same hopping pattern, network address, and security code.
The master and slave have different local addresses.
Both the master and slave have the point-to-point protocol selected on their main serial port.
The point-to-point destination address on the slave is set to the master’s local address, while the
point-to-point destination address on the master is set to the slave’s local address.
6.2 Simplex Point-to-point Network
A simplex point-to-point network is the same as a basic point-to-point network, except that user data is only
going to flow in a single direction. This situation is shown in Figure 15, where user data is only flowing
from the slave to the master unit.
RFI-9256
Master
RFI-9256
Slave
Main
DT
E
Main
DT
E
RADIO CONFIGURATION
Unit is a SLAVE
Network Address: 21
Hopping Pattern: 7
Rx Address: 2000
Directional Bias: Outgoing
PROTOCOL CONFIGURATION
Main Port: Point-to-point to 1000
SERIAL CONFIGURATION
Main Port: 115200, 8N1, Hardware Flow
RADIO CONFIGURATION
Unit is a MASTER
Network Address: 21
Hopping Pattern: 7
Rx Address: 1000
Directional Bias: Incoming
PROTOCOL CONFIGURATION
Main Port: Point-to-point to 2000
SERIAL CONFIGURATION
Main Port: 115200, 8N1, Hardware Flow