Configuration
RFI-9256 Radio Modem User Manual
Page 15 of 109
Response
String
Response
Number
Description
OK
0
The command executed successfully.
CONNECT
1
A connection has been established between this radio and another radio.
RING
2
Another radio is ringing this radio and attempting to establish a
connection.
NO CARRIER
3
A connection could not be established or it has been dropped.
ERROR
4
A command was formatted incorrectly.
BUSY
7
An attempt was made to dial a remote unit and it responded with a busy
signal.
NO ANSWER
8
An attempt was made to dial a remote unit but it could not be contacted
Table 1: AT response codes generated by the RFI-9256
4.4.2 Configuring the Radio
The radio uses s-registers to alter the configuration profile. Each s-register contains a decimal value, an
ASCII character or an ASCII string. The interpretation of each value differs with each s-register.
The radio allows the contents of the s-registers to be saved to non-volatile memory using the
AT&W
command. The entire configuration profile will be retained after the radio has been powered off.
The radio also has factory default settings stored internally, allowing all communication settings and s-
register values to be set to the factory default configuration. The factory defaults have been selected so most
users will be able to make immediate use of their radio, with minimum changes. The default settings are
listed in Appendix D on page 105.
Factory defaults can be restored using the
AT&F
command.
The
AT&V
(view) command outputs the current configuration of the radio.
The complete AT command reference is provided in Appendix C on page 86, while the use of Hayes AT
commands to establish dial-up networking connections is discussed in section 5.3.3 on page 34.
4.4.3 Menu Password Disable
If a menu password has been enabled and access to the internal menu cannot be obtained. The 9256 can be
set back to its factory default configuration by holding down the front button when the power is applied and
typing in the following password after the prompt appears.
*** RFI:
standard
NOTE
: The password needs to be entered in lower case letters