SSD6000W2
14
Ensure the
DSE Mode Switch
is in the
Manual
position.
Once all the
pre-start checks
have been made you can then start the generator. Follow the procedure below:
Press the button until the is displayed on the LCD screen.
A red LED flashes above the button.
You can then safely stop the generator.
Press the button and the generator will immediately stop.
Fig.10
Deep Sea Electronics 3110 - Control Module
This range of generators use a
DSE 3110
control module. The DSE 3110 module is used to start/stop and
monitor key elements of the engine and main AC alternator. The DSE 3110 also has an option of a remote 2-
wire start function. This is used for "Auto" starting/stopping. This function can be carried out with a simple
switch, remote module or an on-demand system.
Manual & 2-Wire Remote (Panel No.7)
This type of SSD6000W2 can be operated (started and stopped) by the DSE 3110 on the generator control
panel manually and it also has the facility to be operated via a 2-wire start function remotely via a switch or
a on-demand switch. The control panel is equipped with a switch to choose either Manual or Auto control.
Warning
Using the Emergency Stop button regularly for a
standard stop request can cause the 12V battery to drain. This
may effect the starting of the generator.
The icon will be displayed on the DSE 3110 module when
an
Emergency Stop
request is made.
The
Emergency Stop
button (DSE 3110 only) is located on the side of the generator canopy -
Fig.10
. It must
be used for emergencies
ONLY
.
DSE 3110 - Manual Start - (Panel No.7 Only)
Press the button once more, the icon rotating will be displayed on
the LCD screen. The engine will then crank and start.
DSE 3110 - Manual Stop - (Panel No.7 Only)
Before stopping the generator in
Manual Mode
it is recommended to
switch off the load
from the generator
by switching the main MCB on the control panel to the "OFF" position (switch down).
Emergency Stop
Содержание SSD6000W2
Страница 30: ......
Страница 35: ...Blank Page...