![Stephill SSD6000W2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/stephill/ssd6000w2/ssd6000w2_operation-manual_1372636011.webp)
SSD6000W2
10
2006/42/EC
The Machinery Directive
2014/30/EU
The Electromagnetic Compatibility Directive
2011/65/EU
The Restriction of Hazardous Substances Directive
All nuts and bolts associated with the lifting beam should be regularly checked for tightness and corrosion.
All Stephill products are fitted with an earth stud on the control panel this must be connected to an earthing
system or spike. Any earth spike required is dependant on the local conditions of use. The size is determined
by reference to current IEE regulations or to a competent electrician.
Lubricating Oil
Safe Lifting
New oil presents no hazard following short term exposure. Lubricants in particular used engine oil, are
potentially carcinogenic. Direct contact should always be avoided by wearing suitable rubber gloves when
handling them. Used oil should not be allowed to contact the skin. If this does occur, wash off quickly with a
proprietary hand cleanser.
Fuels and lubricants are a potential source of fire. Be careful not to spill fuel, clean up any spillages.
Inhalation or swallowing of diesel should be avoided. If in doubt seek medical advice. All other forms of
contact are an irritant and therefore should also be avoided. If skin contact is made wash with soap and
water.
Fuel
General (EU)
Lifting equipment should never be attached directly to the engine and/or alternator to fully lift the generator
except only if lifting engine and/or alternator.
Where mechanical assistance is used in lifting machines, ensure the lifting eye is used, and that all
components used to lift the machine are within their Safe Working Load (SWL).
The integral lifting beam and associated lifting eye on the generator should be regularly checked for signs of
damage or gross corrosion.
DO NOT ATTEMPT TO LIFT THE GENERATOR WITHOUT PRIOR CHECKS TO THE LIFTING
SYSTEM AS INDICATED ABOVE
Fumes
Earth Connection
Make sure that the Generator is at least 2 metres away from any building during operation. Operate in a well
ventilated unconfined area, so that fumes can be properly dispersed. Silencer outlet should be facing an
open area to prevent fumes being recirculated. There is the danger of asphyxiation due to exhaust gases.
Inhalation of poisonous exhaust fumes can lead to serious injury or death. The generator must not be used
in a poorly ventilated or enclosed area.
Содержание SSD6000W2
Страница 30: ......
Страница 35: ...Blank Page...