17
AlphaCom XE - Installation, Configuration & Operation
A100K10805
Performing a Cold Start
2.3
A cold start of the AMC-IP board will delete all previous programming,
load the default database and set the default IP address to 169.254.1.5
with mask 255.255.0.0 on Eth0. See section 3.4 for default settings.
2.3.1 Cold start procedure
Turn the server mains switch ON (at the rear of the cabinet).
●
Press and hold the cold start button on the AMC-IP board.
●
Press the reset button on the APC card briefly.
●
XE7: the reset button is located on the power card
-
XE1: Power up while keeping the cold start button pressed.
-
Keep the cold start button pressed at least 1 second after reset.
●
The AMC status LED will blink green when the boot is ready.
-
2.3.2 Cold start AMC application only (retain IP setting)
Press the reset button on the APC card briefly.
●
XE7: the reset button is located on the power card
-
XE1: Power up while keeping the cold start button pressed.
-
After 10 seconds, press the cold start button on the AMC-IP board.
●
Keep the cold start button pressed until the AMC running LED blinks
●
green.
Modifying Factory Default Settings
2.4
The system is set up with a default program and works without any
further programming. To change or add to the default settings, the
AlphaPro programming tool must be used - see section 5.
Perform System Backup if any default setting has been changed - see
section 12. The default parameters are restored by performing a cold
start - see section 2.3.
Default Directory and Feature Numbers
2.5
2.5.1 Station numbers
The number series 101 to 499 and 5000 to 5152 are default directory
numbers for all AlphaCom XE servers. The directory numbers are
connected to physical numbers in the range from 1 to 552, where the
physical numbers are given by the subscriber point on a board in a
certain position in a defined module.
Since the card positions 2-7 are not used in XE20, the corresponding
default subscriber numbers are missing.
The directory numbers can be changed by using the AlphaPro
programming tool.
ANALOG STATION NUMBER TABLE
AlphaCom modules
XE7
XE20
XE26
Single or master
101 - 136
101 - 106
143 - 238
101 - 238
1
st
slave*
239 - 274
239 - 244
281 - 376
239 - 376
2
nd
slave*
377 - 413
377 - 382
419 - 499
5000 - 5014
377 - 499
5000 - 5014
3
rd
slave*
5015 - 5051
5015 - 5020
5057 - 5152
5015 - 5152
Display text
Station 1, Station 2, etc.
>1 sec
RESET - APC
COLD START - AMC
Status LED
10 sec
RESET - APC
COLD START - AMC
Status LED
XE 26
138
XE 7
XE 20
1
36
80
102
1
2
3
4
5
6
ASLT board
108
109
110
111
112
107
Physical number
1...6
7...12 13...18 19...24 25...30 31...36
Single /first module
Subscriber number
* Slave modules are only required for
analog stations. IP stations are always
registered to the master module.