- CZ": R4 and T5 enable a charging zone control to be created for charging in 2
thermal layers. A detailed functional description of this add-on can be found on page 15.
•
"Basic - R" diagram: In some cases the solar circuit pump must be controlled according to the
solar radiation. For this reason, a S7 radiation sensor must be installed in the collector level. For
control purposes T1 must be inserted between the collector and bypass. A detailed functional
description of this add-on can be found on page 15.
To prevent erroneous settings, the described switch-on and switch-off values are interlocked,
this means they can be set only at a specific value to one other.
Since with this diagram, speed controls are only useful when the objective is "absolute
temperature", this control objective has been saved both in the settings "Absolute temp." and
also "Differential temp.". The control devices are therefore dependent on this setting.
Connecting diagram:
Menu navigation: (here for the scheme 'Basic' )
OK
Measuring values
collector: °C
Operating status
storage bottom:
°C
+Settings
charging temp.
°C
OK OK
storage top:
°C
Parameter
storage max.
70°C
Hot water temp.:
°C
Date / Time
collector max.
130°
charge-pump
Δ
:
h
+Clocks
Diff. temp. solar ON
8K
charge-pump
Σ
:
h
+Service
Diff. temp. solar OFF
4K
discharge-pumpe
Δ
:
h
OK
OK + Menu (2 sec.)
charging temp. max.
115°
discharge-pumpe
Σ
:
h
System selection
-plate heat exchanger
charging setpoint
65°C
solar-pump
Δ
:
h
Functions
OK
AH extern. threshold
0°C
solar-pump
Σ
:
h
Links
-buffer tank with...
storage min.
25°C
Extras
OK
speed control
Manual operation
-fresh water function
OK
~
Basic
choose with OK (2sec.)
{
Basic-CZ
{
Basic-AH
{
Basic-R
{
Basic-R-CZ
T2
T3
T4
T1
R4
S7
T5
R4
T6