Instruction Manual
25
1.
On the View Table Setting page, enter the following information:
•
View Name
: A string identifying the view name that this entry should
belong to.
The allowed string length is 1 to 16.
•
Subtree OID:
The OID defining the root of the subtree to add to the named
view. The allowed string content a is digital number or asterisk (*).
•
Subtree OID Mask:
The bitmask identifies which positions in the specified
object identifier are to be regarded as “wildcards” for the purpose of pattern
matching.
•
View Type
: Indicates the view type that this entry should belong to.
Possible view types are:
•
Included:
An optional flag to indicate that this view subtree should be
included.
•
Excluded:
An optional flag to indicate that this view subtree should be
excluded.
•
General:
If a view entry’s view type is ‘excluded’, it should exist in another
view entry in which view type is ‘included’ and its OID subtree oversteps
the ‘excluded’ view entry.
2.
Click the
Add
button.
Viewing an SNMP Table Status
To view the current status of the SNMP Table.
•
On the
View Table Status
page, the following SNMP information will be
displayed:
•
View Name:
Displays the current SNMP view.
•
Subtree OID:
Displays the current SNMP subtree OID.
•
OID Mask:
Displays the current SNMP OID mask.
•
View Types:
Displays the current SNMP view type.
Deleting an SNMP Entry
•
On the
View Table Status
page, select the
Delete
button under the
Action
field, next to the SNMP entry you wish to delete from the Switch.