Keypad
3-35
SR780 Network Signal Analyzer
[Marker Max]
[Marker Max] moves the Marker to the location of the maximum data value within the
active display. [Marker Max] only searches the data which is in the display. If the
maximum value occurs at more than one location, then the one closest to the left edge is
found.
If the Marker Mode (in the [Marker] menu) is Normal, [Marker Max] centers the marker
region around the maximum. The Marker Seeks Mode chooses whether the Marker seeks
the Maximum, Minimum or Mean of the data within the Marker Region.
For Harmonic or Sideband markers, [Marker Max] moves the Fundamental Marker to the
location of the maximum. [Marker Max] has no affect on Band markers.
[Link] [Marker Max] moves the Marker to the location of the maximum within both
displays.
Command: MKMX d
[Marker Min]
[Marker Min] moves the Marker to the location of the minimum data value within the
active display. [Marker Min] only searches the data which is in the display. If the
minimum value occurs at more than one location, then the one closest to the left edge is
found.
If the Marker Mode (in the [Marker] menu) is Normal, [Marker Min] centers the Marker
Region around the minimum. The Marker Seeks Mode chooses whether the marker seeks
the Maximum, Minimum or Mean of the data within the Marker Region.
For Harmonic or Sideband markers, [Marker Max] moves the Fundamental Marker to the
location of the minimum. [Marker Max] has no affect on Band markers.
[Link] [Marker Min] moves the marker to the location of the minimum within both
displays.
Command: MKMN d
[Show Setup]
[Show Setup] enters the Help system and displays the measurement setup and system
settings. Press [0] to exit Help and return to the measurement displays.
Содержание SR780
Страница 4: ...ii SR780 Network Signal Analyzer ...
Страница 10: ...viii SR780 Network Signal Analyzer ...
Страница 18: ...1 2 Getting Started SR780 Network Signal Analyzer ...
Страница 39: ...Triggering and the Time Record 1 23 SR780 Network Signal Analyzer ...
Страница 40: ...1 24 Triggering and the Time Record SR780 Network Signal Analyzer ...
Страница 58: ...1 42 Waterfall Display SR780 Network Signal Analyzer ...
Страница 70: ...1 54 Saving and Recalling SR780 Network Signal Analyzer ...
Страница 167: ...Status Indicators 3 21 SR780 Network Signal Analyzer ...
Страница 188: ...4 6 Menus SR780 Network Signal Analyzer ...
Страница 193: ...FFT Frequency Menu 4 11 SR780 Network Signal Analyzer Command FEND d f ...
Страница 232: ......
Страница 236: ...4 54 Source Menu SR780 Network Signal Analyzer Command STYP i ...
Страница 266: ...4 84 Playback Input Menu SR780 Network Signal Analyzer ...
Страница 272: ...4 90 Trigger Menu SR780 Network Signal Analyzer ...
Страница 288: ...4 106 Swept Sine Average Menu SR780 Network Signal Analyzer ...
Страница 326: ...144 Exceedance Statistics Menu SR780 Network Signal Analyzer ...
Страница 352: ...4 170 Output Menu SR780 Network Signal Analyzer ...
Страница 478: ......