5-34 Display Setup Commands
SR780 Network Signal Analyzer
YDIV (?) d {, x}
The YDIV command sets (queries) the Y/Division scale of display d. The
parameter x is a real number in the display units. This command is valid for all
Views.
Changing the scale of a display may change the Y Max and Y Mid values.
Always use a YMAX, YMID or YMIN command after the YDIV command.
XCEN (?) d {, x}
The XCEN command sets (queries) the X Center of display d. The parameter x is
a real number in the display units. This command is only valid when the View is
Nichols or Nyquist.
XDIV (?) d {, x}
The XDIV command sets (queries) the polar X/Division scale of display d. The
parameter x is a real number in the display units. This command is only valid
when the View is Nichols or Nyquist.
Changing the scale of a display may change the X Center value. Always use the
XCEN command after the XDIV command.
YCEN (?) d {, x}
The YCEN command sets (queries) the Y Center of display d. The parameter x is
a real number in the display units. This command is only valid when the View is
Nichols or Nyquist.
Y2DV (?) d {, x}
The Y2DV command sets (queries) the polar Y/Division scale of display d. The
parameter x is a real number in the display units. This command is only valid
when the View is Nichols or Nyquist.
Changing the scale of a display may change the Y Center value. Always use the
YCEN command after the Y2DV command.
XPAN (?) d {, i}
The XPAN command sets (queries) the Pan (translation) of display d. The
parameter i is the left most displayed bin. This command is only valid when the
display is Zoomed (expanded).
XZOM (?) d {, i}
The XZOM command sets (queries) the Zoom factor (X axis expand) of display
d. The parameter i is the zoom factor (1-5). This command is not valid when the
X axis is logarithmic or when the View is Nyquist or Nichols.
Содержание SR780
Страница 4: ...ii SR780 Network Signal Analyzer ...
Страница 10: ...viii SR780 Network Signal Analyzer ...
Страница 18: ...1 2 Getting Started SR780 Network Signal Analyzer ...
Страница 39: ...Triggering and the Time Record 1 23 SR780 Network Signal Analyzer ...
Страница 40: ...1 24 Triggering and the Time Record SR780 Network Signal Analyzer ...
Страница 58: ...1 42 Waterfall Display SR780 Network Signal Analyzer ...
Страница 70: ...1 54 Saving and Recalling SR780 Network Signal Analyzer ...
Страница 167: ...Status Indicators 3 21 SR780 Network Signal Analyzer ...
Страница 188: ...4 6 Menus SR780 Network Signal Analyzer ...
Страница 193: ...FFT Frequency Menu 4 11 SR780 Network Signal Analyzer Command FEND d f ...
Страница 232: ......
Страница 236: ...4 54 Source Menu SR780 Network Signal Analyzer Command STYP i ...
Страница 266: ...4 84 Playback Input Menu SR780 Network Signal Analyzer ...
Страница 272: ...4 90 Trigger Menu SR780 Network Signal Analyzer ...
Страница 288: ...4 106 Swept Sine Average Menu SR780 Network Signal Analyzer ...
Страница 326: ...144 Exceedance Statistics Menu SR780 Network Signal Analyzer ...
Страница 352: ...4 170 Output Menu SR780 Network Signal Analyzer ...
Страница 478: ......