Capture
1-31
SR780 Network Signal Analyzer
Press [1] [1] and [Enter].
Enter a zoom factor of 11 (2
11
). The display now
shows the signal sine wave clearly.
7. Unplug the signal from the Ch1 input.
The signal should disappear from the spectrum in
DisplayA.
Press
[Input]
Select the Input menu.
Press <Input Source>
Change the Input Source to measure from the
Capture buffer.
Use the knob to select (Playback) and press
[Enter].
Choose Playback instead of the analog inputs.
The measurement now takes its input from the data
stored in the Ch1 Capture buffer. The signal
reappears in the spectrum in DisplayA.
Only single channel measurements using Ch1 are
allowed in this case (there is no Ch2 data available).
Press <Playback Length>
You can choose to playback only a portion of the
buffer if desired.
Press [1] [9] [8] [0] and [Enter].
Choose the entire buffer by setting the Playback
Length equal to the Capture Length.
Press <Playback Mode>
Playback can be 1-Shot (once through the buffer
and stop) or Circular (repeat when finished).
Use the knob to select (1-Shot) and press
[Enter].
Choose 1-Shot.
Playback stops when the end of the buffer is
reached. The Playback Progress indicator shows the
current position within the buffer during playback.
DisplayB automatically pans to show the portion of
the Capture buffer at the current playback position.
8. Use a BNC TEE to connect the source to both
Ch1 and Ch2 A inputs.
Reconnect the analog signal to both Ch1 and Ch2
inputs.
Press
[Input]
Select the Input menu.
Press <Input Source>
Change the Input Source.
Use the knob to select (Analog) and press
[Enter].
Choose Analog input again. The Capture
parameters can not be modified while the
measurement input is Playback.
Содержание SR780
Страница 4: ...ii SR780 Network Signal Analyzer ...
Страница 10: ...viii SR780 Network Signal Analyzer ...
Страница 18: ...1 2 Getting Started SR780 Network Signal Analyzer ...
Страница 39: ...Triggering and the Time Record 1 23 SR780 Network Signal Analyzer ...
Страница 40: ...1 24 Triggering and the Time Record SR780 Network Signal Analyzer ...
Страница 58: ...1 42 Waterfall Display SR780 Network Signal Analyzer ...
Страница 70: ...1 54 Saving and Recalling SR780 Network Signal Analyzer ...
Страница 167: ...Status Indicators 3 21 SR780 Network Signal Analyzer ...
Страница 188: ...4 6 Menus SR780 Network Signal Analyzer ...
Страница 193: ...FFT Frequency Menu 4 11 SR780 Network Signal Analyzer Command FEND d f ...
Страница 232: ......
Страница 236: ...4 54 Source Menu SR780 Network Signal Analyzer Command STYP i ...
Страница 266: ...4 84 Playback Input Menu SR780 Network Signal Analyzer ...
Страница 272: ...4 90 Trigger Menu SR780 Network Signal Analyzer ...
Страница 288: ...4 106 Swept Sine Average Menu SR780 Network Signal Analyzer ...
Страница 326: ...144 Exceedance Statistics Menu SR780 Network Signal Analyzer ...
Страница 352: ...4 170 Output Menu SR780 Network Signal Analyzer ...
Страница 478: ......