5
F. FLUE CONNECTION VENTILATION:
Installation under ventilation hood (standard):
Local inspectors and ventilation specialists should be consulted so that the design and the installation of
the hood conform to local/municipal codes. In the U.K., follow ventilation requirements as detailed in
B.S. 5440.
NOTE: DO NOT PUT A DAMPER IN THE FLUE AND DO NOT CONNECT A BLOWER DIRECTLY
TO THE FLUE.
If the flue runs directly to the free air outside the building, use a wind deflector or a UL listed vent cap at
the end of the pipe. Termination of the vent must be at least two feet above the highest part of the roof
within ten feet. REF: AGACATALOG NO. Xh0474.
G. INITIAL CLEANING:
Always clean equipment thoroughly before first use. Clean the protective oil from the metal parts and
interior of baking chamber with a solution of washing soda or the other grease dissolving material.
H. SYSTEM CHECK- ROTARY CONTROL (standard):
(1) Open the oven door.
(2) Turn Selector Switch to “HI.” The green indicator light near Selector Switch and oven light will
illuminate.
(3) Close the door. Oven lights will go off and fan will run. Make sure fan is rotating clockwise
looking from front.
(4) Press Oven Light switch. Oven light will go on and will go off as switch is released.
(5) Turn the thermostat knob. The amber indicator light near the thermostat will illuminate and the
heating elements will come on.
(6) Turn the timer knob past 10 minutes and back to 2 minutes. At the end of 2 minutes the buzzer
will sound. Reset by turning to “0.” All settings below 10 minutes require turning past 10
minutes and then back to the time required.
(7) Open the oven doors. Oven lights will go on and elements and fan will go off.
(8) Turn Selector Switch to “Cool Down” position. The fan will run to cool down the oven.
(9) Turn Selector Switch to “0” position.
(10) Close the oven doors.
NOTE: WITH THE DOORS CLOSED, THE POWER SWITCH “ON” AND THE SELECTOR SWITCH
IS IN ANY POSITION OTHER THAN “0”, THE OVEN WILL START HEATING AS SOON AS THE
SET TEMPERATURE IS HIGHER THAN THE OVEN TEMPERATURE.
THERMOSTAT INDICATOR LIGHT GOES OUT WHEN OVEN REACHES SET TEMPERATURE AND
COMES ON WHEN OVEN IS HEATING UP.
IN THE EVENT OF POWER FAILURE, THE OVEN WILL NOT OPERATE.
PROGRAMMING MENUS:
See Operating/Programming Instruction Booklet for
Programmable Oven Control with Bakers Pride Software for Cyclone Series
Convection Ovens supplied with this option.