Suitable for installation on combustible floor when installed with legs or casters
provided.
CAUTION:
Do not set the oven with its back flat against the wall. It will not
operate properly unless there is at least three inches breathing space behind the
oven
NOTICE:
Local codes regarding installation vary greatly from one area to
another. The National Fire Protection Association, Inc., states in it’s NFPA 96
latest edition that local codes are “authority having jurisdiction” when it comes to
requirements for installation of equipment. Therefore, installations should comply
with all local codes.
E. ELECTRICAL CONNECTION:
Install according to the spacing requirements listed in the installation section of this manual. We
strongly recommend having a competent professional install this equipment. A licensed electrician
should make the electrical connections and connect power to the unit. Local codes should always be
used when connecting these units to electrical power. In the absence of local codes, use the latest
version of the National Electrical Code.
Note: For supply connections use No. 6 AWG wires suitable for at least 90°C.
The oven, when installed, must be electrically grounded in accordance with local codes and/or the latest
edition of the National Electrical Code ANSI/NFPA No. 70 in the USA (Canadian Electrical Code CSA
Standard C22.1, Part 1 in Canada).
In Europe, the appliance must be connected by an earthen cable to all other units in the complete
installation and, thence, to an independent earth connection in compliance with EN 60335-1 and/or
local codes.
Electrical power is to be supplied to the oven(s) by means of hard wiring, which is to be performed by a
qualified licensed electrician.
a) Adequate means must be provided to limit the movement of the appliance without depending on
or transmitting stress to the electrical conduit.
b) The location(s) where restraining means are to be attached to the appliance shall be specified.
c) The appliance shall be installed using flexible conduit.
TSCO-E1, TSDCO-E1
Model
KW
Voltage
Phase
Amps
Motor-50hz
Motor-60hz
Line 1
Line 2
Line 3
N
RPM
(Low)
RPM
(High)
RPM
(Low)
RPM
(High)
BCO-E,
GDCO-E
10.5
208
1
48
48
-
-
725
1425
850
1725
10.5
208
3
30
30
28
-
725
1425
850
1725
10.5
220-240
1
44
44
-
-
725
1425
850
1725
10.5
220-240
3
26
26
24
-
725
1425
850
1725
Each oven requires separate electrical connections
Normal factory connections are made for 208 V. A.C. or 208/240 V.A.C., 60 Hz.
This unit is provided with a permanently lubricated electric motor. A wiring diagram may be found on the
back of the service panel on the right-hand side and also in this manual.