The  unit  is  in  the  Operating  Mode. The  actual  temperature  is  shown  in  the  display  and  is 
within 20 degrees of the programmed temperature.  

The  unit  is  in  the Operating  Mode.  The  actual  temperature  will  flash  in  the  display  and  is 
more than 20 degrees below the programmed temperature range.  

The unit is in the Operating Mode. The flashing display signifies a cook cycle has just been 
completed.  

The unit is in the Operating Mode. With three zeros displayed, the probe has failed, or the 
appliance  has  gone  beyond  operating  temperature.  Shut  the  appliance  OFF  immediately 
and call a technician.  

CONTROLLER FEATURES

  

Fahrenheit or Celsius Temperature Display 

The operator is allowed to configure the controller to display the temperature in degrees Fahrenheit or 
Celsius  from the jumper  on the  back  of  the  circuit  board  (J3).  By  default,  the  unit  is  shipped from the 
factory in Fahrenheit (J3 not shorted), unless otherwise specified by the customer. For Celsius display, 
power  unit  down,  remove  jumper  from  Pin  1  and  short  both  pins.  When  power  is  re-applied,  the 
controller will be in Celsius operation.  

Programmable Times 

The  operator  will  have  the  ability  to 
program the cook times for each product 
key.  The  controller  is  programmable  in 
minutes  (up  to  59)  and  seconds  (up  to 
59), then hours (up to 99).  

Programmable Temperatures  

The  operator  will  be  able  to  program 
cook temperatures for each product key. 
The  valid  temperature  range  is  150  to 
550°F (66 to 288°C).  

Programmable Hold  

The  operator  will  be  able  to  program  each  product  key  for  a  counting  hold  time  and  temperature  
(140 to 200°F/60 to 94°C) or disable the hold mode.  
HOLD LIGHT (LED) ON = hold mode enabled  
HOLD LIGHT (LED) OFF = hold mode disabled. 

Programmable Fan 

The operator will be able to program each product key for one of two fan modes.  
FAN LIGHT (LED) ON = Fan always ON  
FAN LIGHT (LED) Flashing = Fan pulsed  

Flashing Display 

The temperature display will flash after every product key is pressed. The display will continue to flash 
until the actual temperature is within 20° of set temperature.  

Содержание TRI-STAR CO11-E

Страница 1: ...operty damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this equipment WARNING Initial heating of oven may generate smoke o...

Страница 2: ...the outside carton regarding damage in transit Damage discovered after opening the carton is CONCEALED DAMAGE Carrier must be notified immediately to send an inspector and to furnish forms for claims...

Страница 3: ...Insert Open Rack Shelf and tighten into place with eight 3 8 16 screws washers and nuts 4 Position Rack Supports and tighten in place using 4 each of flat washers and 5 16 18 Hex Nuts C INSTALLATION W...

Страница 4: ...ith local codes and or the latest edition of the National Electrical Code ANSI NFPA No 70 in the USA Canadian Electrical Code CSA Standard C22 1 Part 1 in Canada In Europe the appliance must be connec...

Страница 5: ...n will run Make sure fan is rotating clockwise looking from front 4 Press Oven Light switch Oven light will go on and will go off as switch is released 5 Turn the thermostat knob The amber indicator l...

Страница 6: ...6 Remove the product from the oven when done Timed cooking rotary control 1 Close the oven doors 2 Turn Selector Switch to HI or LO position The indicator light near the Selector Switch will be illum...

Страница 7: ...up is made make sure that there are no leaks For steam injection press the Steam switch momentarily NOTE DO NOT USE STEAM INJECTION AT TEMPERATURES BELOW 275 F 135 C Oven cool down Rotary control To c...

Страница 8: ...o start a timing cycle In operating and programming mode used to increase or decrease the time In operating and programming mode used to increase or decrease the temperature When lit steady denotes fa...

Страница 9: ...ill now operate and cool down the oven When the oven has cooled to the desired temperature turn the selector switch to the 0 position OPERATING NOTES When the oven is turned on it will automatically p...

Страница 10: ...otherwise specified by the customer For Celsius display power unit down remove jumper from Pin 1 and short both pins When power is re applied the controller will be in Celsius operation Programmable T...

Страница 11: ...ow key to the right of the temperature display The longer you press the key the faster the display will change To select the hold feature and set the holding temperature press and hold the HOLD key th...

Страница 12: ...ved for stainless steel NEVER use cleaning solvents with a hydrocarbon base NEVER use a wire brush steel or abrasive scouring pads scraper file or other steel tools NOTE ALWAYS RUB THE STAINLESS STEEL...

Страница 13: ...toll free 800 431 2745 for an authorized service agency in your area WARNING RISK OF FIRE When stacked two high maximum use stacking kit part E3771A only CAUTION This product when stacked has more th...

Страница 14: ...3 4 5 6 21796810 8633515 8227700 8509300 8435000 82447 00 Weldment Oven Leg Foot Insert Adjustable Hex Hd 5 16 18 X Bolt 5 Zn Washer Flat SAE 5 16 Hex nut 5 16 18 Hex Hd 3 8 16 X 750 5 1 Attach two i...

Страница 15: ...ke longer or raise oven temperature slightly Do not open doors to oven for long periods Cake ripples Overloading pans or batter is too thin Reduce pan loads Thicken batter Cakes are too coarse Thermos...

Страница 16: ...16 F Wiring Diagram TSCO E1 TSDCO E1 208V 240V 1 Phase Dial Control P N 8806675 Wiring Diagram TSCO E1 TSDCO E1 208V 240V 3 Phase Dial Control P N 8806674...

Страница 17: ...17 Wiring Diagram TSDCO E1 208V 240V 1 Phase Push Button Control P N 8806677 Wiring Diagram TSDCO E1 208V 240V 3 Phase Push Button Control P N 8806678...

Страница 18: ...18 Wiring Diagram TSCO E1 TSDCO E1 230V 400V 3 Phase 4 Wire Dial Control EXPORT P N 8806676 STEAM INJECTION WIRING DIAGRAM 220V 240V 02 11 10 REV...

Страница 19: ...___________________________________________________________ __________________________________________________________________________________ _________________________________________________________...

Страница 20: ...AR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the con...

Страница 21: ...21 TRI STAR MANUFACTURING 729 3rd Avenue Dallas TX 75226 Phone 1 714 424 9380 Fax 1 714 424 9385 Website www tri starmfg com Toll Free 1 866 782 7462 E mail tristarmfg sbcglobal net...