- 76 -
EN
displacement.
•
The temperature in the room where the cylinders are installed must not exceed 35 °C.
The fryer may be connected to a propane-butane tank or gas installation only by a person authori
-
zed to perform installation services. Adaptations of the fryer to another type of gas must be carried
out by an authorized fitter.
The installation and replacement of nozzles must be certified by the relevant warranty card ac
-
companying the product
LPG fryer should be connected to a hose (hose for propane-butane with safety mark „B”) via seamless steel
tubing with a length of at least 50cm. The cable should be secured with clamps at both ends against slipping. The
length of the hose cannot be less than 1.2 m and cannot exceed 1.5 m. The propane-butane (B/P) gas cylinder
must be equipped with a gas pressure reducer up to 3.7kPa
Fryers running on natural gas (E) should be connected to the gas network inside the building rigidly or by
means of flexible metal hoses with an updated safety mark. Use a pipe union and a 1/2” seamless pipe. The fryer
has a threaded connection with an R 1/2” thread.
During the first installation of the device and after each change of supply (another type of gas), the supply
pressure must be verified with a manometer. The spigot for pressure checks is on the supply pipe (near gas inlet
connection) behind the door and on the thermostatic gas valve (side body). After removing the cap on spigot
and connecting the manometer through a flexible hose, the pressure shall be measured with the appliance on
and the value of supply pressure must be included between the minimum and maximum values according to
the type of gas