© 2022 Staheli West
252
13
15
17
14
16
18
Connect an air compressor to the red igniter cleanout
hose.
Unscrew the flame detector.
Unscrew the lens.
Open and close the valve several times to clean the
burner igniter assembly.
Clean the flame detector lens.
50 Hour Maintenance
Remove the inner air filter. Clean both using
compressed air. Then reinstall the air filters and end
cap.