© 2022 Staheli West
188
Faults
Fault 313: Touch Screen Problems: Frozen, Won’t Respond to Touch...
Causes
Troubleshooting
Fixes
• Faulty USB flash drive.
• Is the screen locking up or
displaying one of the messages
below?
• Replace USB flash drive
(8gb or smaller).
Error message: EA9 An attempt was made to access \Hard Disk\Log\.........
• Application Error; Application
EA-RUN.exe encountered 1-.
• Reset panel to factory default by entering programming mode on
the touch screen. Press and hold top left corner of touch screen for up
to 5 seconds. Press “Memory” then press “Reset to factory default”.
This can take several minutes. Do not turn off touch screen. Reload
firmware and project after touch screen has been reset.
• No system found.
• Factory reset screen then program screen. (See above for “Reset to
factory default” procedure)
• Faulty software.
• Reprogram touch screen with appropriate software.
• Faulty touch screen.
• Order new touch screen.
• Faulty PLC.
• Pressing confirm start doesn’t
do anything. It stays on the same
screen. No control over valves in
Manual Mode.
• Reprogram the PLC.
• Replace PLC.
Fault 314: Failed PTO Bearing(s)
Indicates poor driveline quality.
*2015 machines had old style bearings. If one or more fail, all should be replaced with the new style
bearings, and get the adapter kit.
**2016 machines and newer have the new style bearings.
Causes
Troubleshooting
Fixes
• Not greasing bearings every 50
hours.
• If there is play/movement in
the PTO shaft, this indicates that
your bearings have failed.
• If there is rattling or knocking
sounds, this indicates that your
bearings have failed.
• Replace PTO bearings.
• Bad PTO shaft angles.
• Turning too sharp.
• Stopping too abruptly.
• PTO front and rear knuckles
aren’t aligned causing vibration.