OPERATING INSTRUCTIONS 

 

 

 

 

18 

3.2 

Storage 

It is advisable to store the unit in dry conditions. 

The  pump  has to be protected against penetra-

tion of dirty parts. 

Description  

4.1 

Construction 

Speck  liquid-ring  vakuum  pumps  of  the  types 

VZ  ..G  are  dual-stage  pumps  on  base  plate 

construction.  The  shafts  are  mounted  on  ball 

bearings  at  both  ends.  The  shafts  are  sealed 

with two mechanical seals (Version 470). 
Speck  liquid-ring  vakuum  pumps  of  the  types 

VZ ..B are dual-stage pumps in block construc-

tion  The  shafts  are  mounted  on  ball  bearings 

at  both  ends.  The  shafts  are  sealed  with  two 

mechanical seals (Version 470). 

4.2 

Function 

The liquid ring rotates inside the working area 

eccentrically  to  the  shaft.  The  impeller  trans-

mits  the  drive  performance  by  the  circulating 

liquid ring as compression power to the gas to 

be  delivered.  This  produces  low  pulsation 

compression.  

The  service  liquid  -  normally  water  -  must  be 

added  and  cooled  continuously.  This  dissi-

pates the resulting compression heat and adds 

liquid  to  the  ring,  since  part  of  the  liquid  is 

continuously  dissipated along with the gas on 

the pressure side. The liquid can be separated 

from  the  gas  in  a  discharge  separator  at-

tached. 
 

Illustr. 1: 

function 

 

Set up and Installation 

CAUTION

 

The  non-observation  of  all  safety  informa-

tions 

given 

under 

“5 

Setting 

up/Installation”  shall  invalidate  any  claims 

of warranty including claims for compensa-

tion of damages. 

5.1 

Place of Installation 

Always  choose  a  place  of  installation,  where 

pump and motor are easily accessible. 

5.2 

Installation  

The complete pump unit has to be put on a flat 

and plain base plate. The base plate/foot has 

to be screwed without warping to the ground 

or the equipment frame. 
If  the  floor  is  uneven,  chock  up  the  base 

plate/foot with appropriate flat objects, cement 

or similar. Any warping of the base plate badly 

affects  the  alignment  of  the  coupling.  It  is 

advisable  to  check  the  alignment  of  the  cou-

pling with a ruler or a gauge (before and) after 

tightening the base plate. 

CAUTION

 

In  case  the  coupling  is  not  aligned,  the 

smooth  running  of  the  pump  will  be  dis-

turbed  and  the  bearings  will  be  worn  out 

and consequently the pump may get defec-

tive early! 
 

Illustr.

 2:

 

alignment of coupling 

 

 

 

A  guard  corresponding  DIN  31001  must  pre-

vent  the  coupling  from  being  touched.  The 

pump  body  can  also  be  warped  by  incorrect 

fastening.  

If  low  vibration  running  is  a  high  priority,  the 

unit  must  be  fixed  to  a  vibration  insulated 

foundation  (with  no  fixed  connection  between 

the  base  plate  and  the  foundation  or  the 

equipment frame).  
You must lay the piping to the plant such that 

on  the  inlet  side  there  is  an  incline  to  the 

Содержание VZ 11 B Series

Страница 1: ...H CO KG zertifiziert DIN EN ISO 9001 Betriebsanleitung Operating Instructions Mode d emploi Fl ssigkeitsring Vakuumpumpen Liquid Ring Vacuum Pumps Pompes vide anneau liquide VZ 110B VZ 180B VZ 110G VZ...

Страница 2: ...nzip 5 5 Aufstellung Einbau 5 5 1 Aufstellungsort 5 5 2 Einbau 5 5 3 Leitungen 6 5 3 1 Saugleitung 6 5 3 2 Druckleitung 6 5 4 Elektrischer Anschluss 6 5 5 Betriebsarten 7 5 5 1 Offene Umlaufk hlung 7...

Страница 3: ...lnbetriebnahme vom Monteur sowie dem zust ndigen Fachpersonal Betrei ber zu lesen und muss st ndig am Einsatzort der Pumpe Anlage verf gbar sein Es sind nicht nur die unter diesem Hauptpunkt Si cherh...

Страница 4: ...siehe z B Vorschriften des VDE und der rtlichen Energieversorgungsunter nehmen 2 6 Sicherheitshinweise f r War tungs Inspektions und Monta gearbeiten Der Betreiber hat daf r zu sorgen dass alle Wartu...

Страница 5: ...ne pulsation sarme Verdichtung Eine kontinuierliche Zuf hrung bzw K hlung der Betriebsfl ssigkeit im Normalfall Wasser ist erforderlich Sie f hrt die entstehende Ver dichtungsw rme ab und erg nzt die...

Страница 6: ...me zu pr fen 5 3 1 Saugleitung In der Saugleitung sollte ein R ckschlagventil eingebaut werden um das F llen der Vakuum leitung mit der Ringfl ssigkeit bzw um Druck abfall im Vakuum System zu vermeide...

Страница 7: ...it kein Wert gelegt wird Der Aufbau erfolgt nach Abb 5a Der An schluss UU wird verschlossen Die Betriebs fl ssigkeit B besteht aus Frischfl ssigkeit F Der erforderliche Frischfl ssigkeitsdruck soll 0...

Страница 8: ...turf hler zu rF2 UA Fl ssigkeitsablauf UB Anschluss f r Betriebsfl ssigkeit UN Anschluss f r Kontrollventil US Saugleitungsanschluss DU Druckleitungsanschluss UU Anschluss f r Umlauffl ssigkeit Ue Ent...

Страница 9: ...BETRIEBSANLEITUNG 9 Durchlaufk hlung Abb 4a nebenst Fl ssikeitsabscheider Abb 4b Fl ssigkeits Aufbauabscheider Beh lter mit Schwimmerventil Abb 4c nebenst Fl ssigkeitsabscheider...

Страница 10: ...BETRIEBSANLEITUNG 10 Geschlossene Umlauflaufk hlung Abb 5a nebenstehender Fl ssigkeitsabscheider Abb 5b Fl ssigkeits Aufbauabscheider Abb 6 Lage des Betriebswasseranschlusses...

Страница 11: ...s ue3 ein Ventil angeschlossen werden Ein automatisches Entleerungsventil an diesem Anschluss kontrolliert und reguliert den Fl ssigkeitsstand selbstt tig 6 3 3 Durchlaufk hlung nach Abb 4 Bei laufend...

Страница 12: ...eingestellt werden dass das gew nschte Saugverm gen bzw der gew nschte Volu menstrom erreicht jedoch Kavitation verhin dert wird Das Regulierventil ist in dieser Ein stellung zu blockieren Bei Vakuumb...

Страница 13: ...d ebenso des Saugverm gens eintritt siehe 7 2 Temperatur der Fl ssigkeit durch geeig nete Ma nahmen senken Gas bzw Fl ssigkeitskan le verschlossen Pumpe zerlegen und besonders die Kan le reinigen Glei...

Страница 14: ...2200 Gaseintrittstemperatur trocken 160 C wasserdampfges ttigt 80 C VZ 110 180 Drehzahl min 1 50Hz 60 Hz 1450 1750 Betriebsfl ssigkeit Temperatur 10 C 60 C Dichte 1200 kg m3 Viskosit t 4 mm2 s berdruc...

Страница 15: ...stallation 18 5 2 Installation 18 5 3 Pipes 19 5 3 1 Suction pipes 19 5 3 2 Discharge Pipes 19 5 4 Electrical connection 19 5 5 Operation modes 19 5 5 1 Open circulation cooling 19 5 5 2 Closed circul...

Страница 16: ...mp s place of opera tion at all times You should not just consider the general safety information listed in this point specific safety information is also con tained in the other main points 2 1 Marki...

Страница 17: ...ts who are adequately informed having thor oughly read these operating instructions Basically the pump must have stopped before carrying out any work on it The procedures described in the operating in...

Страница 18: ...Installation CAUTION The non observation of all safety informa tions given under 5 Setting up Installation shall invalidate any claims of warranty including claims for compensa tion of damages 5 1 Pla...

Страница 19: ...faultless electrical installation required taking into account appropriate guide lines and VDE regulations serious consideration is necessary of the pump s direction of rotation flow direction which i...

Страница 20: ...p will be provided with a gas ejector pump 5 6 Setting up of the unit A side mounted liquid separator has to be installed thus that the liquid discharge is at the same level as the shaft The liquid se...

Страница 21: ...PERATING INSTRUCTIONS 21 Setting up schema Open circulating cooling illustr 3a side mounted separator illustr 3b top mounted separator Illustr 3c thermostatically controlled process liquid temperature...

Страница 22: ...OPERATING INSTRUCTIONS 22 Continuous cooling Illustr 4a side mounted separator Illustr 4b top mounted separator Tank with float valve fitted Illustr 5a side mounted separator...

Страница 23: ...OPERATING INSTRUCTIONS 23 Closed circulation cooling Illustr 5a side mounted separator Illustr 4b top mounted separator Illustr 6 position of service liquid connection...

Страница 24: ...e connection Ue3 An automatic draining valve at this connection controles and regulates the liquid level auto matically 6 3 3 Continuous cooling according to illustr 5a Open shut off valve VF while th...

Страница 25: ...ty resp a reduced volume flow however gives the possibility of safing fresh water resp cooling liquid at open resp closed circulation cooling Such liquid quantity should be regulated by the regulating...

Страница 26: ...ozzle IG elevated by 300 mm or through a connecting pipe with nozzle to the liquid separator a The use of a gas ejector also avoids cavitation If a large amount of dirt is deposited it should be remov...

Страница 27: ...e 7 2 Reduce the temperature by suitable means gas resp liquid channels are closed disassembly the pump and especially clean the channels mechanical seal is leaking change mechanical seal pump does no...

Страница 28: ...200 compression pressure mbar 2500 2200 2200 gas entry temperature r dry vapour saturated 160 C 80 C speed min 1 VZ 110 180 50Hz 60 Hz 1450 1750 service liquid temperature 10 C 60 C density 1200 kg m3...

Страница 29: ...2 Mise en Place 32 5 3 Tuyauteries 33 5 3 1 Tubulure d aspiration 33 5 3 2 Tubulure de refoulement 33 5 4 Branchement lectrique 33 5 5 Modes de fonctionnement 34 5 5 1 R frig ration par circulation ou...

Страница 30: ...e monteur et le personnel sp cialis l exploitant avant le montage et la mise en service et qu il soit toujours disponible sur le lieu de la pompe de l installation En plus des r gles de s curit mentio...

Страница 31: ...ue doit tre exclu pour les d tails consulter les prescriptions sp cifiques du pays ainsi que celles des usines d lectricit locales 2 6 Instructions de s curiti pour l entretien inspection et travaux d...

Страница 32: ...cr un effet de compression impulsions r duites Il est necessaire d alimenter resp refrig rer continuellement le liquide de service norma lement de l eau Il dissipe la chaleur de com pression cr e et...

Страница 33: ...un clapet anti retour devrait tre install afin d viter que la conduite vide se rempli avec liquide de service resp afin d viter une chute de pression dans le syst me vide S il y a un organe d arr t va...

Страница 34: ...disponible en quantit suffisante et que l on n attache pas d int r t au recyclage du liquide de fonctionnement Si le gaz et le liquide ne doivent pas obligatoi rement tre vacu s s par ment on peut ren...

Страница 35: ...rin age UL Raccord pour robinet d a ration Sch ma d installation Refroidissement par circulation en circuit ouvert Fig 3a S parateur mont s par ment Fig 3b S parateur rapport Fig 3c R gulation thermo...

Страница 36: ...MODE D EMPLOI 36 Refroidissement en circuit ouvert Fig 4a S parateur mont s par ment Fig 4b S parateur rapport Fig 4c R servoir avec robinet flotteur...

Страница 37: ...MODE D EMPLOI 37 Refroidissement par circulation en circuit ferm Fig 5a S parateur mont s par ment Fig 5b S parateur rapport Fig 6 Emplacement du raccord d eau de fonctionnement...

Страница 38: ...e d arr t VK est ouverte Arr ter les robinets de r glage dans leur position Afin de contr ler le niveau de liquide N on peut raccorder une vanne au raccord Ue3 Une vanne de vidange automatique dans ce...

Страница 39: ...ique indiqu dans les prospectus et catalogues est obtenu pour une temp rature d eau de fonc tionnement de 15 C Un fonctionnement une temp rature d eau de fonctionnement plus lev e se traduit par une r...

Страница 40: ...u par le raccord de protection de cavitation une petite quantit de gaz qui ne condense pas la compression Ceci peut s effectuer par un robinet d a ration h une conduite remontant d environ 300 mm avec...

Страница 41: ...onter la pompe et nettoyer les canalisations Garniture m canique non tanche Remplacer la garniture m canique La pompe n atteint pas le vide voulu pression d bit D bit d eau d coulement A trop petit V...

Страница 42: ...de compression mbar 2500 2200 2200 temp rature d aspiration du gaz sec 160 C satur en vapeur d eau 80 C VZ 110 180 vitesse de rotation min 1 50Hz 60 Hz 1450 1750 anneau liquide temp rature 10 C 60 C p...

Страница 43: ...billes 330 Lagertr ger Bearing housing Corps paliers 360 1 2 Lagerdeckel Earing cover Convercle de roulement 411 1 3 Dichtring Joint ring Garniture d tanch it 412 O Ring o ring Joint torique 441 Geh...

Страница 44: ...MODE D EMPLOI 44 VZ B...

Страница 45: ...MODE D EMPLOI 45 VZ G...

Страница 46: ...MODE D EMPLOI 46...

Страница 47: ...MODE D EMPLOI 47...

Страница 48: ...05 Adresse SPECK PUMPEN Walter Speck GmbH CO KG Regensburger Ring 6 8 D 91154 Roth Tel 49 09171 809 0 Fax 49 09171 809 10 e mail info speck pumps d internet http www speck pumps de Vervielf ltigung je...

Отзывы: