Cannot record.
SRMemory card is write-protected. Return the write-protect switch to the original
position.
Power to other
equipment does not
come on.
Power switch of other equipment is
not on.
Turn power switch of other equipment on.
Low voltage.
The power cable is too long,
causing a voltage drop.
If the power cable is too long or does not have
a sufficient current capacity rating, cable
impedance can cause a voltage drop. Replace
the cable with a shorter one.
Battery alarms appear
frequently.
If battery alarms appear even when
the input voltage is sufficient, the
END and NEAR END settings for
the DC power supply are wrong.
Change the END and NEAR END settings to
suitable voltage settings for the DC power
supply.