13.Appendix F: AIT based WORM system
13-2 SONY AIT-5 drive SDX-1100V series Ver.1.0
How to initialize a WORM cartridge to AIT Native mode.
1Partition
AIT=1, DEVICE=1, ABS=1, SysLogAlive=11, Span=0Ah
Set IDP bit to 1. Additional Partition=0.
13.5.
How to handle the WORM cartridge in the drive.
1.
DATA READ: There is no restriction when reading data in WORM mode.
2.
DATA WRITE: Any attempt to overwrite existing data will be rejected with a Check Condition status and
sense data.
●
Write Projected Error: 07-27-00-07 (Sense Key, ASC, ASCQ, Run-time-error)
●
Append Position Error: 03-27-04-f7
The AIT WORM drive will allow write operations when:
(1) Append Write Operation is allowed only at End-Of-Data (EOD) area. Prior to an Append Write Operation,
several commands can be used to position the drive at EOD area:
●
Space to EOD (space code 3)
●
Space to last record (could be a block, File-mark, Set-mark)
●
Locate to last block
●
Read until EOD
For example:
No
Yes
Mode Sense (Page 31h)
Mode Select (Page 31h)
Mode Select (Page 11h)
Space EOD
Write
Write End
END
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...