6.Command Specification
READ ATTRIBUTE
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-66
Table 6-66: READ ATTRIBUTE service action codes
Code Name
Description
00h
Attribute Values
Return attribute values.
01h
Attribute List
Returns a list of available attribute identifiers, identifiers
that are not in the nonexistent or unsupported state.
02h
Volume List
Return a list of known Volume Numbers.
03h
Partition List
Return a list of known Partition Numbers.
04h
Reserved for SMC-2
05h – 1Fh
Reserved
The VOLUME NUMBER specifies a volume within the Medium Auxiliary Memory. The number of volumes of the
MAM will equal that of the attached multi-volume medium. If the medium only has a single volume, then its volume
number will be zero.
The PARTITION NUMBER specifies a partition within a volume. The number of partitions of the MAM will equal
that of the attached multi-partition medium. If the medium only has a single partition, then its partition number will
be zero.
If the combination of VOLUME NUMBER and PARTITION NUMBER is not valid, the command will be terminated
with a CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST, and the additional sense
data will be set to INVALID FIELD IN CDB.
The FIRST ATTRIBUTE IDENTIFIER field specifies the attribute identifier of the first attribute to be returned. If the
specified attribute identifier is in the unsupported or nonexistent state, the READ ATTRIBUTE will be terminated
with a CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST, and the additional sense
data will be set to INVALID FIELD IN CDB.
The ALLOCATION LENGTH field specifies how many bytes have been allocated of the first attribute to be
returned. If the length is not sufficient to contain the entire parameter list, the first portion of the list will be
returned. This will not be considered an error. If the remainder of the list is required, the application client will either
send a new READ ATRRIBUTE command with an ALLOCATION LENGTH field large enough to contain the entire
parameter list or use the FIRST ATTRIBUTE IDENTIFIER field to restrict the attributes returned.
The format of parameter data returned by the READ ATTRIBUTE command depends on the service action
specified.
6.13.1.
ATTRIBUTE VALUES service action
The READ ATTRIBUTE command with ATTRIBUTE VALUES service action returns parameter data containing
the attributes specified by the PARTITION NUMBER, VOLUME NUMBER, and FIRST ATTRIBUTE INDENTIFIER
fields in the CDB. The returned parameter data will contain the requested attributes in ascending numerical order
by attribute identifier value and in the format shown in Table 6-67.
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...